Connection Options
65
Steps to Take
1.
Start the COMfortel Set configuration software.
2.
Click Options.
3.
Click Interface.
4.
USB connection: Select the USB interface, and click
OK.
USB connection using the CAPI 2.0 driver installed:
Select the ISDN controller (CAPI 2.0) interface, and
click OK.
Ethernet connection via the PBX: Select the IP
network interface, enter the IP address for the PBX,
and click OK.
5.
Click Open.
6.
Click Telephone.
The current connection to the PBX is displayed.
7.
Double-click the system symbol to display all the
connected system telephones.
8.
Click the system telephone to be configured, and then
click OK.
The login window opens.
9.
Select the authorisation level you want on the PBX,
enter the applicable PIN, and click OK.
NoteFor COMfort 1000/1200/2000 system
telephones, you only need to enter the 6-digit system
telephone PIN – if available.
The configuration is loaded.
10.
Configure the settings you want.
NoteOnce you have configured all the settings to
your satisfaction, first save the configuration as a file
on the hard drive and then in the telephone.
11.
Click Save.
12.
Click File.
13.
Enter a name for the file and click OK.
14.
Click Save.
15.
Click Telephone.
The current connection to the PBX is displayed.
16.
Double-click the system symbol to display all the
connected system telephones.
17.
Click the system telephone to be configured, and then
click OK.
The login window opens.
18.
Select the authorisation level you want on the PBX,
enter the applicable PIN, and click OK.
The configuration is saved.
Configuring System Telephones Remotely via the PBX
Important: Before you can configure the system
telephones remotely, you must first configure the
settings listed at the end in the PBX.
Requirements
– On the page COMset
General settings
Remote
configuration Configured remote switching number
for system telephones
Note: If no remote switching number has been
configured, the PBX must be enabled internally for
remote configuration using the programming function.
See
. After this, the PBX is accessible over
each associated MSN/DDI.
– On the page COMset
General settings
Remote
configuration Configured dealer access number
Note: You can enter up to four telephone numbers as
dealer access numbers; one of these numbers must
be transmitted during a remote configuration.
Note: If no dealer access numbers have been
entered or the telephone number transmitted does
not correspond with the ones entered, the PBX must
be enabled internally for remote configuration using
the programming function. See
.
– Existing external ISDN connection between a compu-
ter and a PBX via one of the following devices:
Auerswald USB device (for example, a COMfortel
2500)
ISDN PC controller
– Completed installation of the device driver