1062
COMmander 6000/R/RX - Firmware V7.0D - Advanced Information V19 04/2018
Appendix Hardware
Buttons
1. Press the
Reset
button (for COMmander 6000 on the base circuit
board; for COMmander 6000R/6000RX at the front of casing).
2. Press the
SW default
button (for COMmander 6000 on the base circuit
board; for COMmander 6000R/6000RX at the front of casing) within 2
seconds and hold it down between 10 and 15 seconds.
The
Power
LED starts to quickly blink in red.
After 5 seconds the LED
Status
starts to blink slowly.
3. Let go of the
SW default
button.
The factory settings are restored and the PBX restarts.
If the
Power
LED lights up in green again, the restart is complete and
the PBX is ready for operation.
Note:
If the
Power
LED remains continuously lit in red, an error has occurred.
Please contact your dealer or the manufacturer directly.
If you release the
SW default
button too late (the
Power
LED is no
longer flashing), restart the PBX without making any changes.
Shutting the PBX Down by Pressing a Button
Requirements:
•
COMmander 6000R or 6000RX
•
Delayed powering down: Press the
Power
button for 1,5 to 4 seconds.