Functional Overview
a/b-Audiobox - Operation Guide - V03 10/2020
35
This chapter provides you with an overview that summarises the available programming and
operating functions.
Overview of Programming Functions
Functional Overview
Description
Func
-
tion
Value
Switching audio transmission on
establishment of connection on/off
28
1
(on),
0
(off)
Switching sound of the gong
before the announcement on/off
71
1
(on),
0
(off)
Setting the volume
57
0
(quiet) to
9
(loud)
Setting maximum connection time
51
0
(unlimited),
1
(1 min) to
9
(9 min)
Setting time to wait for silence
detection or switching off silence
detection
59
0
(silence detection off),
1
(1 s) to
9
(9 s)
Setting the input sensitivity of the
a/b line
50
0
(low) to
9
(high)
Switching the switching function
during establishment of connec
-
tion on/off
60
1
(on),
0
(off)
Setting the switching time of the
switching function
61
00
(duration of the announce
-
ment),
01
(1 s) to
90
(90 s)
Switching over a switching func
-
tion manually
63
Assigning a/b switching modules
to the switching function
32
0
(none),
1
(switching frequency 1) to
6
(switching frequency 6)
Assigning a/b switching modules
to the key on the device
31
0
(none),
1
(switching frequency 1) to
6
(switching frequency 6)