INSTALLATION
PILOT
-C14-
MANUAL
-
15
The
Pilot
will indicate when set-up has been achieved:
And will automatically put itself in standby mode.
The
Pilot
can be left in this state until fi rst use.
5.8 - Step 5: Finishing set-up
5.9 - 1st use
To turn on the
Pilot
, press
.
Long pressing
puts the
Pilot
in standby mode.
The purging cycle is launched for a duration of 30 minutes and will
automatically stop after that time is up.
At any time during the cycle, you can:
- Interrupt (or resume) the cycle by pressing on
.
- End the cycle and continue to the next step by pressing
5.6 - Step 3: Purging the installation
During the cycle, check that the automatic purgers are open and
regularly activate the manual purgers.
If the pressure in the circuit becomes insuffi
cient due to the volume
of air purged, the
Pilot
will indicate it and will pause
the purging cycle.
Activate the backfl ow prevention device or the fi lling valve to raise
the pressure. The purging cycle will resume automatically once there
is suffi
cient pressure.
During the purging cycle, the screen
indicates the countdown until the
automatic stop of the cycle as well as
the pressure in the circuit.
The purging cycle activates the circulator pump at an alternating
rhythm to allow the displacement and purging of any air bubbles
accumulated at high points of the installation using the
Pilot’s
automatic purger.
5.7 - Step 4 : Choosing the back-up
It is possible to select the electrical back-up, the back-up boiler or
not to declare a back-up.
AIR BLEED