2.1 - Storage
STORAGE AND INSTALLATION
PRECAUTIONS:
•The appliance must not be stored in an enclosed
space of less than 4m
2
without ventilation.
• If the appliance is to be stored in a space with
less than 4m
2
of surface area (e.g. in a cupboard)
there must be ventilation points at the top and
bottom of this space.
Authorised transport positions :
All other transport positions are prohibited.
2- RECOMMENDATIONS
• Verify that the ventilation openings are not
obstructed.
• A
new
pressure-relief valve (not included)
must
be installed and set to 6 bars on the domestic
cold water supply of the appliance. The use of
a membrane valve is recommended.
• This valve must conform to all national standards
in effect.
•The pressure-relief drainage outlet should
be installed in a frost-free place and in a
downward sloping position.
- Maintenance - Troubleshooting -
• Drainage : Turn off the power supply and the
cold water, open the hot water valves and then
set the safety group to the drainage position.
• The pressure-relief valve should be activated
regularly so as to eliminate limescale and check
for blockages.
•.If the electrical supply cable is damaged, it
must be replaced by the manufacturer, their
customer service technicians, or by a qualified
professional to avoid risk of injury.
• See the § «Dimensions» (page 5) and the §
«Installation» (page 6) of this manual to find the
necessary dimensions for proper installation of
this appliance.
• See the § «Hydraulic connections» (page 7) of
this manual to find the minimum and maximum
water pressures and temperatures.
WARNING
Do not use any methods to accelerate the
defrosting or cleaning process other than
those recommended by the manufacturer.
The appliance must be stored in a room which
does not contain a perpetual flame or other
source of ignition (for example: open flame,
gas powered appliances or electric radiators
in use).
Do not pierce or burn.
Warning:
refrigerant fluids may be odourless.
The appliance must be installed, used, and
stored in a room larger than 4m².
The appliance can only function when filled
with water. Never turn on the appliance if the
tank has not been properly filled with water
and completely purged of air.
2.2 - Transport
Admissible transport and storage temperatures of the heat pump
water heater are between -20
o
C and +60
o
C.
Transporting the appliance in a
horizontal position may lead to
irreparable damage to the components of the
Heat Pump.
All other transport positions are
PROHIBITED.
It is preferable to transport the heat pump water heater in its original
packaging to protect the appliance.
Non-authorised transport positions :
-
installer
HEAT PUMP WATER HEATER 200 -270L AIR D/2 -
manual
-
-
installer
HEAT PUMP WATER HEATER 200 -270L AIR D/2 -
manual
-