4.5.1.4 - Connection to the photovoltaic function (PV)
This function enables the
appliance to operate in auto-
production mode, which
means that it will use the
energy produced by the PV
function to supply the heat
pump as well as the electrical
back-up, and to heat the water
in the tank.
The connection is made
between the energy manager
electrical box (not supplied)
and connectors 1 and 2 on the electronics board.
• Remove the protective casing.
• Remove the black cover from the electronics board.
• Connect the PV function cable to connector 1 on the electronics board.
• If the PV function regulator has two control contacts, connect them to connectors 1 and
2 on the electronics board. See § « Electrical box electrical diagram » in the appendix. .
• Terminal 1: a low level of electrical energy is produced by the PV function.
• Terminal 2: a high level of electrical energy is produced by the PV function.
CAUTION: Connectors 1 and 2 are for DRY CONTACTS ONLY. They must NEVER be connected to 230V.
Deterioration risk: the water tank must be
filled before the appliance is switched on
or connected to a power supply.
5.1 - Control panel
5 - SET-UP AND USE
• Leave the appliance unplugged.
• Open the hot water outlet which is located the highest on the
appliance.
• Open the cold water inlet on the pressure-relief valve.
• Fill the tank until water is coming out of the highest outlet.
• Close the hot water outlet.
Before turning the appliance on, ensure that the entire circuit is
watertight.
The heat pump water heater operates
primarily
with
the
heat pump
as long as the air intake temperature remains in
the authorised range from -7°C à +35°C. Outside of this range, the
electrical back-up ensures the heating of domestic hot water.
The temperature of the domestic hot water provided by the heat
pump is adjustable up to 60°C.
In the case of high domestic hot water consumption, the heat
pump water heater has a comfort function,
t
°
C mini
which
increases the heating capacity when there is less than 1/3 of
the tank’s volume left at over 38°C (see § «
t
°
c mini
-minimum
temperature-»). There is also a setting to activate the electrical
back-up if the heating time is too long (see § «
max time
»).
If more domestic hot water is required from time to time, the heat
pump water heater has a «
boost
» function (activated by the user)
which ensures that the water heats to the desired temperature
(
for example : 50°C
) quickly with the help of the heat pump and
electrical back-up, This function is deactivated as soon
as the required temperature is reached.
From time to time, check that there are no alerts (in case of an
alert, please refer to § «Error messages»).
..... Compressor activated
..... Fan activated
........ Defrosting in progress
........ Electrical back-up
activated
.... Domestic hot water
requested
.... Comfort mode in
progress
....... Eco mode in progress
....... Freeze protection mode
in progress
...... Holiday mode in progress
..... Keyboard locked
......... Settings/parameters
being displayed
.... PV mode activated
1 2 3
...
7
. Date
Pictograms:
-
installer