Operation
20
5.3 Stopping the sealer (S
TANDBY
mode)
After use, stop the sealer as follows to put it in S
TANDBY
mode:
1. Press
the
START
/
STOP
button for 1 sec.
The sealer will now switch to
S
TANDBY
mode; the display will
show a point in the bottom right-
hand corner of the display.
When the sealing temperature is
over 80°C, the sealer will first
switch to
C
OOLRUN
mode. The
heating is switched off and the
blower and the motor will continue
to run until the sealing temperature
has dropped to below 80°C. The
display will alternate between show
"c-r" and the "actual temperature".
After that, the sealer is
automatically switched to
S
TANDBY
mode.
When the
START
/
STOP
button is
pressed for longer than 3
seconds, the sealer will
immediately switch to
S
TANDBY
mode, even if the sealing
temperature is higher than 80°C.
Use this way of switching off
only if absolutely necessary. It
may cause the PTFE fibreglass
belts to burn sooner.
If the sealer is not going to be used
for a longer period of time, it is
better to switch it off completely
by removing the plug from the
socket.