background image

VENU series 

USER’S MANUAL V1.0

Page   of 

1

19

AUDIOFOCUS VENU series

USER’S MANUAL V1.0

Summary of Contents for VENU series

Page 1: ...VENU series USER S MANUAL V1 0 Page of 1 19 AUDIOFOCUS VENU series USER S MANUAL V1 0 ...

Page 2: ...Page of 2 19 AUDIOFOCUS VENU series USER S MANUAL V1 0 ...

Page 3: ...ION 3 2 VENU series 3 3 LOW END 3 4 HARDWARE AND COVER 4 SETUP 4 1 VOLUME 4 2 PRESET SELECTION 4 3 DELAY 4 4 EASEFOCUS PREDICTION 4 5 DIRECTIVITY 4 6 RIGGING 4 7 WIRING 4 8 ETHERNET PORT 4 9 MAINTENANCE 5 TECHNICAL SPECIFICATIONS 6 CONTACT AND LINK Page of 3 19 AUDIOFOCUS VENU series USER S MANUAL V1 0 ...

Page 4: ... A2 2005 EN61000 3 2 2000 A2 2005 EN61000 3 2 2295 A1 2001 A2 2005 Ing Xavier Marchal Audiofocus R D Director Maximum load have been tested and approved by Vinçotte s a CERTEST Products 2 2 HANDLING Keep this device away from rain and moisture AUDIOFOCUS is not responsible for third party material use for example foot lift 2 3 SOUND LEVEL VENU series can deliver high sound pressure level that coul...

Page 5: ...ind the VENU series to be highly versatile units in your professional sound reinforcement inventory 3 2 VENU series VENU series are high end two ways versatile speaker that can also be used on a stand as a FOH alone or with subwoofer or as a monitor suitable for a wide range of sound reinforcement applications from small to medium scale concerts installation or theater where sound quality is cruci...

Page 6: ... LOW END 3 3 1 S15 S18 S21 VENU series can be used with the S series self powered subwoofer System can be configured as needed 3 4 HARDWARE AND COVER Page of 6 19 AUDIOFOCUS VENU series USER S MANUAL V1 0 ...

Page 7: ...sunshine Ambient temperature and amplifier temperature are related but not the same amplifier start limiting at 75 c Flightcase for VENU series and rain cover are recommended to ensure a long life to the system 4 SETUP Page of 7 19 AUDIOFOCUS VENU series USER S MANUAL V1 0 ...

Page 8: ... preset engage They will display the level setting while changing level and delay setting while changing delay Fonction description Preset description 4 1 VOLUME Page of 8 19 AUDIOFOCUS VENU series USER S MANUAL V1 0 Encoder Status LED Signal LED ...

Page 9: ...es amplifier come with 4 presets choices Preset 1 EXTENDED Preset with low end extension which give the feel of a subwoofer addition Preset 2 FULL RANGE Preset used with the combination of a subwoofer Preset 3 MONITOR Preset when VENU is set up as a floor monitor Preset4 HP Preset without low end to maximise the power on the vocal frequency range Can be used in a four way configuration too Preset ...

Page 10: ...g the rotative encoder 5seconds give access to delay selection Each step is 5meters delay increase For longer or accurate tuning use the AFNetworkManager software Page of 10 19 AUDIOFOCUS VENU series USER S MANUAL V1 0 ...

Page 11: ... 15 have a directivity of 60 x100 The horn directivity of VENU12 and VENU15 can be adjusted regarding the need of the configuration and this with every preset in used Front grill must be removed and horn unscrewed to be adjusted 4 6 RIGGING VENU series can be hang using AUDIOFOCUS accessories Page of 11 19 AUDIOFOCUS VENU series USER S MANUAL V1 0 ...

Page 12: ...VENU series can also be hang by using the M8 port on the side of the cabinet with proper eye bolt Page of 12 19 AUDIOFOCUS VENU series USER S MANUAL V1 0 ...

Page 13: ...ve speaker are recommended Connect power and signal cables as describe on the technical drawing Make sure the preset volume are right Check the signal output before application Page of 13 19 AUDIOFOCUS VENU series USER S MANUAL V1 0 XLR OUTPUT XLR INPUT POWERCON LINK POWERCON INPUT AFMANAGER AESOP DANTE option ENCODER ...

Page 14: ... manual for more information RJ45 port can handle both AF network manager AESOP and Dante option at the same time 4 9 MAINTENANCE Remove the cover if any liquid hit it let it dry If you need to clean it use no agressive product for synthetic material You want to have regular check of the general aspect of the cabinet Wood paint part can be clean with maintenance furniture product metal part with a...

Page 15: ...ge directivity 6dB 80 conical Active Input impedance 10 kΩ balanced Passive impedance 8ohm Passive sensitivity 1W 1m 95dBSPL RMS power handling Passive 400Wrms 800W peak Active 500Wrms 800W peak Wedge angle 40 from vertical left and right mirror wedge Connectors Analog AES RJ45 Dante RJ45 Weight Active 11 5kg 25 4lb Passive 10 1kg 22 3 lb Baltic birch plywood Finish Black polyurethane coating UV r...

Page 16: ...ty 6dB 80 conical Active Input impedance 10 kΩ balanced Passive impedance 8ohm Passive sensitivity 1W 1m 97dBSPL RMS power handling Passive 400Wrms 800W peak Active 500Wrms 800W peak Wedge angle 45 from vertical left and right mirror wedge Connectors Analog AES RJ45 Dante RJ45 Weight Active 15 5kg 34 2lb Passive 14 6kg 32 2 lb Baltic birch plywood Finish Black polyurethane coating UV resistant Dim...

Page 17: ...100 x60 rotative horn Active Input impedance 10 kΩ balanced Passive impedance 8ohm Passive sensitivity 1W 1m 97dBSPL RMS power handling Passive 600Wrms 1600W peak Active 1000Wrms 1800W peak Wedge angle 45 from vertical left and right mirror wedge Connectors Analog AES RJ45 Dante RJ45 Weight Active 18 5kg 40 8lb Passive 17 3kg 38 1 lb Baltic birch plywood Finish Black polyurethane coating UV resist...

Page 18: ...orn Active Input impedance 10 kΩ balanced Passive impedance 8ohm Passive sensitivity 1W 1m 97dBSPL RMS power handling Passive 900Wrms 1800W peak Active 1100Wrms 2000W peak Wedge angle 45 from vertical left and right mirror wedge Connectors Analog AES RJ45 Dante RJ45 Weight Active 18 5kg 40 8lb Passive 17 3kg 38 1 lb Baltic birch plywood Finish Black polyurethane coating UV resistant Dimensions HxW...

Page 19: ...info audiofocus eu www facebook com AudiofocusPage www facebook com groups AUDIOFOCUS Page of 19 19 AUDIOFOCUS VENU series USER S MANUAL V1 0 ...

Reviews: