Parameter
Description
(configured by the parameter HotLineToneDuration), the
destination phone number is automatically dialed.
Module = Module number (where 1 depicts the module in Slot 1).
Port = Port number (where 1 depicts the Port 1 of the module).
For example:
TargetOfChannel 0 = 1002,1,1,1; (phone number "1002" is automatically
dialed for Port 1 of Module 1)
TargetOfChannel 1 = 101,1,1,2; (phone number "101" is automatically
dialed for Port 2 of Module 1)
Notes:
The indexing of this ini file table parameter starts at 0.
Define this parameter for each device port that implements Automatic
Dialing.
After a ring signal is detected on an 'Enabled' FXO port, the device
initiates a call to the destination number without seizing the line. The
line is seized only after the call is answered. After a ring signal is
detected on a 'Disabled' or 'Hotline' FXO port, the device seizes the
line.
For configuring this table using the Web interface, refer to ''Configuring
Automatic Dialing'' on page
For an explanation on using
ini
file table parameters, refer to ''Format of
ini File Table Parameters'' on page
6.8.11 Direct Inward Dialing Parameters
The Direct Inward Dialing (DID) parameters are described in the table below.
Table
6-40: DID Parameters
Parameter
Description
Web/EMS: Enable DID
Wink
[EnableDIDWink]
Enables Direct Inward Dialing (DID) using Wink-Start signaling.
[0]
Disable = Disables DID Wink(default).
[1]
Enable = Enables DID Wink.
If enabled, the device can be used for connection to EIA/TIA-464B DID
Loop Start lines. Both FXO (detection) and FXS (generation) are
supported. An FXO interface dials DTMF digits after a Wink signal is
detected (instead of a Dial tone). An FXS interface generates the Wink
signal after the detection of off-hook (instead of playing a Dial tone).
Web/EMS: Delay Before
DID Wink
[DelayBeforeDIDWink]
Defines the time interval (in msec) between detection of off-hook and
generation of a DID Wink.
The valid range is 0 to 1,000. The default value is 0.
Note:
This parameters is applicable only to FXS interfaces.
Summary of Contents for mediapack MP-500
Page 1: ...Document LTRT 12801 October 2009 User s Manual Version 5 8...
Page 2: ......
Page 22: ...SIP User s Manual 22 Document LTRT 12801 MP 500 MSBG Reader s Notes...
Page 24: ...SIP User s Manual 24 Document LTRT 12801 MP 500 MSBG Reader s Notes...
Page 290: ...SIP User s Manual 290 Document LTRT 12801 MP 500 MSBG Reader s Notes...
Page 440: ...SIP User s Manual 440 Document LTRT 12801 MP 500 MSBG Reader s Notes...
Page 564: ...SIP User s Manual 564 Document LTRT 12801 MP 500 MSBG Reader s Notes...
Page 566: ...SIP User s Manual 566 Document LTRT 12801 MP 500 MSBG Reader s Notes...
Page 573: ...Version 5 8 573 October 2009 SIP User s Manual 13 Technical Specifications Reader s Notes...
Page 574: ...User s Manual Version 5 8 www audiocodes com...