CHAPTER 34 Basic Maintenance
Mediant 4000 SBC | User's Manual
34
Basic Maintenance
This section describes basic maintenance.
Resetting the Device
You can reset the device through the device's management tools. Device reset may be required for
maintenance purposes. Certain parameters require a device reset for their settings to take effect.
These parameters are displayed in the Web interface with the lightning
symbol. In addition,
whenever you do any configuration change that requires a reset, the
Reset
button on the Web
interface's toolbar is displayed with a red border, as shown below:
The Web interface also provides you with the following options when resetting the device:
■
Save current configuration to the device's flash memory (non-volatile) prior to reset
■
Reset the device only after a user-defined time (G
raceful Shutdown
) to allow current calls to
end (calls are terminated after this interval)
To reset the device (and save configuration to flash) through CLI, use the following command:
# reset now
➢
To reset the device through Web interface:
1.
Open the Maintenance Actions page:
●
Toolbar: Click the
Reset
button.
●
Navigation tree:
Setup
menu >
Administration
tab >
Maintenance
folder >
Maintenance
Actions
.
2.
From the 'Save To Flash' drop-down list, select one of the following:
●
Yes:
Current configuration is saved (
burned
) to flash memory prior to reset (default).
●
No:
The device resets without saving the current configuration to flash. All configuration
done after the last configuration save will be discarded (lost) after reset.
3.
From the 'Graceful Option' drop-down list, select one of the following:
●
Yes:
Reset starts only after a user-defined time, configured in the 'Shutdown Timeout' field
(see next step). During this interval, no new traffic is accepted. If no traffic exists and the
time has not yet expired, the device resets immediately.
●
No:
Reset begins immediately, regardless of traffic. Any existing traffic is immediately
terminated.
4.
In the 'Shutdown Timeout' field (available only if the 'Graceful Option' field is configured to
Yes
), enter the time after which the device resets. Note that if no traffic exists and the time has
not yet expired, the device resets.
5.
Click the
Reset
button; a confirmation message box appears, requesting you to confirm.
- 653 -
Summary of Contents for Mediant 4000 SBC
Page 1: ...User s Manual AudioCodes Series of Session Border Controllers SBC Mediant 4000 SBC Version 7 2...
Page 40: ...Part I Getting Started with Initial Connectivity...
Page 48: ...Part II Management Tools...
Page 113: ...Part III General System Settings...
Page 118: ...Part IV General VoIP Configuration...
Page 525: ...Part V Session Border Controller Application...
Page 654: ...Part VI Cloud Resilience Package...
Page 663: ...Part VII High Availability System...
Page 685: ...Part VIII Maintenance...
Page 759: ...Part IX Status Performance Monitoring and Reporting...
Page 844: ...Part X Diagnostics...
Page 888: ...Part XI Appendix...