![AudioCodes Mediant 3000 TP-6310 Performance Monitoring And Alarm Manual Download Page 140](http://html1.mh-extra.com/html/audiocodes/mediant-3000-tp-6310/mediant-3000-tp-6310_performance-monitoring-and-alarm-manual_3011240140.webp)
Performance Monitoring and Alarms
140
Document #: LTRT-32111
Mediant 3000 with TP-6310
3.4.49
DS3 AIS Alarm
This alarm applies only to Mediant 3000 TP-6310.
DS3 AIS Alarm
Description
This alarm is issued when the AIS condition is present on the DS3
Interface #m.
SNMP Alarm
acDS3AISAlarm
SNMP OID
1.3.6.1.4.1.5003.9.10.1.21.2.0.67
Alarm Title
DS3 AIS Alarm
Alarm Source
Interfaces#0/DS3#<m>
Alarm Type
communicationsAlarm
Probable Cause
receiveFailure
Severity
Critical / Cleared
Additional Info
Corrective Action
Check the following and correct according to the appropriate reason:
There is a SONET level failure: LOS, LOF, AIS-L, AIS-P, UNEQ-P, TIM-
P
The far-end (e.g., MUX) sends a DS3 AIS
3.4.50
DS3 LOF Alarm
This alarm applies only to Mediant 3000 TP-6310.
DS3 LOF Alarm
Description
This alarm is issued when the LOF condition is present on the DS3
Interface #m.
SNMP Alarm
acDS3LOFAlarm
SNMP OID
1.3.6.1.4.1.5003.9.10.1.21.2.0.68
Alarm Title
DS3 LOF Alarm
Alarm Source
Interfaces#0/DS3#<m>
Alarm Type
communicationsAlarm
Probable Cause
receiveFailure
Severity
Critical / Cleared
Additional Info
Corrective Action
Check and correct the DS3 framing