![AudioCodes Mediant 3000 TP-6310 Performance Monitoring And Alarm Manual Download Page 119](http://html1.mh-extra.com/html/audiocodes/mediant-3000-tp-6310/mediant-3000-tp-6310_performance-monitoring-and-alarm-manual_3011240119.webp)
Version 7.0
119
Performance Monitoring and Alarms
Performance Monitoring and Alarms
3. Alarms
3.4.25
User Input Alarm
User Input Alarm
Description
Sent when the input dry contact is short circuited; cleared when the
circuit is reopened.
SNMP Alarm
acUserInputAlarm
SNMP OID
1.3.6.1.4.1.5003.9.10.1.21.2.0.36
Alarm Source
Chassis#0
Alarm Type
equipmentAlarm
Probable Cause
inputDeviceError
Alarm Severity
Condition
<text>
Corrective Action
Critical
(default)
Input dry contact is short
circuited.
User input Alarm.
User's Input-Alarm
turn on.
Reopen the input dry
contact.
Cleared
Input dry contact circuit is
reopened.
-
3.4.26
D-Channel Status
D-Channel Status
Description
Non-alarm trap sent at the establishment, re-establishment or release of
LAPD link with its peer connection occurs. The trap is sent with one of
the following textual descriptions:
•
D-channel synchronized
•
D-channel not-synchronized
SNMP Alarm
acDChannelStatus
SNMP OID
1.3.6.1.4.1.5003.9.10.1.21.2.0.37
Alarm Title
D-Channel Status
Alarm Source
Trunk no.<m> where m is the trunk number (from 0 up).
Alarm Type
Communications Alarm
Probable Cause
Communications Protocol Error
Severity
Minor on raise, Clear on clear
Additional Info
-
Corrective Action
-