Performance Monitoring and Alarms
110
Document #: LTRT-32111
Mediant 3000 with TP-6310
3.4.19
Power Supply Alarm
Power Supply Alarm
Description
This alarm is activated in one of the following cases:
The HA (High Availability) feature is active and one of the power
supply units is faulty or missing.
PS unit is inserted in its location and functioning.
SNMP Alarm
acPowerSupplyAlarm
SNMP OID
1.3.6.1.4.1.5003.9.10.1.21.2.0.30
Alarm Source
Chassis#0/PowerSupply#<m>, where
m
is the power supply’s slot
number
Alarm Type
equipmentAlarm
Probable Cause
powerProblem
Alarm Severity
Condition
<text>
Corrective Action
Major (default)
The HA (High
Availability) feature is
active (applicable only
to Mediant 3000) and
one of the power
supply units is faulty or
missing.
Power-Supply Alarm.
Power-Supply is
missing.
1.
Check if the unit is
inserted in the
chassis.
2.
If it was removed
from the chassis,
re-insert it.
3.
If it's inserted in the
chassis and the
alarm is active,
send a Return
Merchandise
Authorization
(RMA) request to
AudioCodes.
Cleared
PS unit is placed and
working.
-
-