background image

User Manual

Flush-mount Microphone Socket with LED Ring and Touch Switch   

AT8657/LED-S

 

Features

 

Connection procedure

AT8657/LED-S requires 24-48 V 
DC phantom power.

Audio-Technica Corporation

2-46-1 Nishi-naruse, Machida, Tokyo 194-8666, Japan

©2017  Audio-Technica Corporation

Global Support Contact: www.at-globalsupport.com

20-JAN-2021     Form No.ATGC-L0392-21

(Unit: mm)

Thank you for purchasing this product. Before using the product, read 
through the user manual to ensure that you will use the product correctly.  
Please keep this manual for future reference.

Connect the output terminals of AT8657/LED-S  to a device that hava a 

microphone input (balanced input) compatible with a phantom power supply,  

a switch logic control output and a LED logic input . The input / output connectors are 

XLRM-type with polarity as 

shown in the figure below.

• Flush-mount microphone socket for the AT846C / AT846O or any phantom-powered 

gooseneck microphone with a 3-pin XLRM-type output and a base diameter no 

greater than 21 mm

• Mounts unobtrusively in tabletops
• Switch logic output permits control of remote devices from built-in capacitance switch
• Integral, phantom-powered, Green/Red LED indicator ring
• Operates on 24-48V DC phantom power
• 3-pin XLRF-type connector for microphone, 5-pin XLRM-type connector for output
• Lock tab in socket case automatically locks microphone in place, holding it there until 

tab is manually released by user

• Isolators provide mechanical dampening of mounting-surface vibration

• Low-profile design with low-reflectance black finish for minimum visibility

Dimensions

55

Description

The AT8657/LED-S flush-mount microphone socket features a capacitive-type touch- 

sensitive switch, Red/Green LED indicator ring, switch logic output for controlling 

remote devices and a lock tab to hold microphone in place. The socket is equipped with 

a three-pin XLRF-type in, and a five-pin XLRM-type output connector.

The AT8657/LED-S requires 24-48V DC phantom power for operation. The electronics in 

the socket take up to 30 seconds to stabilize after power is applied; during this start-up 

period, some sonic disturbances may be heard upon switching if the system is "live."
The touch-sensitive switch can be used to trigger an external device.
The lock tab, located in the socket case, automatically engages when microphone is 

inserted, securely holding it in place until tab is manually released by user.
The output of the socket is a 5-pin XLRM-type connector.
Isolators are included with the unit for mechanical isolation from the mounting surface. 

A retaining ring is also included for use with gooseneck microphones. The socket is 

enclosed in a heavy-duty die-cast case. The low-profile housing has a low-reflectance 

black finish.

Microphone input terminals

PIN2 (hot)

PIN3 
(cold)

PIN1 (ground)

PIN1

(ground)

PIN5

(LED Input)

PIN4

(Switch Logic)

PIN2

(Audio +)

PIN3 (Audio -)

Output terminals

5

4

3

2

1

 

Specifications

360 Ohms
High (+5V DC) when pressed;

Red when high (+5V DC), Green when low (0V DC),

-0.5V to 5.5V
24-48V DC, 4 mA typical
Touch-sensitive control : momentary
165 g
130.6 mm long, 55.0 mm maximum width
3-pin XLRF-type

Output impedance

Switch logic

LED input

Phantom power requirements

Switch

Weight

Dimensions

Intput connector

5-pin XLRM-type
One pair isolators, one set metal retainer ring

Output connector

Accessories furnished

Low (0V DC) when not pressed

-0.5V to 5.5V

I/O voltage

Maximum input voltage

22.8

44.0

10.4

4.1

54.0

130.6

30.0

33.5

19.0

Surface

Isolator

(upper)

Surface

Isolator

(lower)

Mounting

Nut

Release

Tab

Installation and Operation

The AT8657/LED-S requires 24-48V DC phantom power for operation.
Output is low impedance (Lo-Z) balanced. The signal appears across Pins 2 and 3; Pin 

1 is ground (shield). Output phase is "Pin 2 hot" - positive acoustic pressure produces 

positive voltage at Pin 2. Switch logic output appears between pins 1 and 4. LED logic 

input appears between pins 1 and 5.

The microphone socket should be installed on a flat, unobstructed mounting surface.

The AT8657/LED-S should be mounted to a tabletop using the included isolators in 

order to dampen surface vibration. To mount the socket with the isolators, a 35 mm 

hole is recommended. Place the isolators on either side of the hole to achieve 

mechanical isolation from the mounting surface.
The AT8657/LED-S's capacitive-type touch-sensitive switch allows the user to trigger 

a function on an external device: Switch logic output is High (+5V DC) when pressed. 

Low (0V DC) when not pressed.
The LED indicator ring lights red when logic high (+5V DC) and green when logic low 

(0V DC).

Reviews: