Now we must configure our Mains transformer for the World Voltage that we reside in.
For this example we will show
120V Operation
.
Start by cutting two short pieces of
wire approx 2” in length each, stripping
the insulation off the ends and tinning
the wire.
Then we will inter-wire the Mains transformer primaries.
Remember, we are wiring here for 120v - if your region is
different then you will need to consult the wiring chart on
the previous page to determine how you inter-wire for your
region.
From the IEC bag we want to take the brown and blue
wires with the crimps on one end.
Trim the wires to about _____ inches in length and then
solder on to the correct Mains transformer primary tags for