DVD-201-01(-02, -03)-x Installation & Operation Manual
Document # 540211, Rev C, 05/2002
Page 9 of 24
3.13
ESD
(Electro Static Discharge) guidelines shall be followed.
4.0 Wiring
Requirements
4.1 Introduction
The installing agency shall supply and fabricate all external cables. The
length and routing of external cables shall be carefully studied and
planned before attempting installation of the equipment. Allow adequate
space for installation of cable and connectors. Avoid sharp bends and
placing cables near aircraft control cables. Maintain a minimum clearance
of three (3) inches from any control cable. If wiring is run parallel to
combustible fluid or oxygen lines, maintain a separation of six (6)
inches
between the lines.
4.2 Power Wires
All power and ground wires shall be 22 AWG, MINIMUM
,
shielded twisted
pair with the shield properly bonded at one end only. Power ground wires
shall be bonded to electrically conductive chassis mounting point with
<1
Ω
resistance or <50
Ω
impedance. Twisted shielded pair cable shall be
in accordance with the standard military specification of
MIL-DTL-27500
or equivalent.
4.3 Video Lines
Composite video connections shall be shielded coaxial cable in
accordance with the military specifications of
M17/94-RG179
or
equivalent.