Page 1: ...IN THE EAR HEARING AIDS sino kami rega User Manual ...

Page 2: ...e 6 2 2 Technical features 6 2 3 Batteries 7 2 3 1 Information on batteries 7 2 3 2 Low battery warning 8 3 OPERATION SINO KAMI REGA 9 3 1 Construction 9 3 2 Inserting batteries 10 3 3 Removing batteries 11 3 4 Switching hearing aids on and off 12 3 5 Inserting and removing hearing aids 12 3 6 Volume control and program selection 14 3 6 1 Volume control 14 3 6 2 Selecting hearing programs 15 4 TIN...

Page 3: ...on the sticker on the packaging on the warranty card or printed on the hearing aids themselves Please take note of the following Your hearing aid will not make your hearing normal again nor will it prevent or improve any physical hearing loss If you fail to wear your hearing aid regularly you will not benefit fully from it Use of a hearing aid only accounts for part of your hearing ability and may...

Page 4: ...longer when it is sealed Removing the protective strip allows oxygen to enter and the chemical reaction is initiated Refitting the strip when the battery is not in use will not extend its service life 2 YOUR HEARING AID 2 1 Type Your hearing aids are in the ear hearing aids 2 2 Technical features This user manual applies to the following types The detailed acoustic data of your hearing aid can be ...

Page 5: ... Construction 1 2 3 1 2 3 4 Battery should be stored at room temperature Avoid keeping them in hot places or rooms with high humidity e g bathroom Storage in a cooled location is not necessary Used batteries are considered hazardous materials and contain toxic materials should never be disposed of in the trash Ask about recycling programs in your area where you live or return them to your hearing ...

Page 6: ...w minutes before inserting the battery Open the battery compartment carefully with your fingernail at the edge for opening and swing it right out Then insert the battery in the battery compartment Make sure the symbol on the battery matches the symbol on the battery compartment Note Do not force the battery into the battery compartment If it does not fit check whether you are inserting it correctl...

Page 7: ...ds Depending on the model your hearing aids have markings for the sides blue left red right Before use check that your hearing aids are clean After use earwax and other residues may be present on your hearing aids Remove before using again After a preset delay and a start up jingle the first program will activate and the hearing aids are ready for use Switching off The hearing aids are switched of...

Page 8: ...ted An audible signal confirms each program change Hearing program 1 2 3 4 Description of setting When you switch your hearing aids on they will be at the volume set for you Increase volume Slowly turn the controller forwards Reduce volume Slowly turn the controller backwards Once you have reached the upper or lower volume limit you will hear a clear signal 3 6 1 Volume selection 3 6 Volume contro...

Page 9: ...itch either to telephone loop Auto T Coil or to a microphone program for telephony Auto Phone To prevent the hearing aids from accidentally switching programmes during a telephone call the program switch is disabled during this time 4 TINNITUS FUNCTION Combi hearing aids from audifon play an effective part in tinnitus therapy Your hearing care professional would have adjusted the combi hearing aid...

Page 10: ...tion works before making a call When you move the telephone handset away from your ear again your hearing aids will return to the program previously in use 5 2 2 Auto Phone Automatic switchover to an acoustic telephone program can be used with conventional landline and mobile phones and optimises playback for telephony Attaching the optional magnet sticker increases the reliability of the switchin...

Page 11: ...the long term un less dried on a daily basis The hearing aids are coated with a water repellent finish to prevent any damage from moisture Wearing a hearing aid or insertion of the ear adapter piece in the ear canal will always involve soiling with earwax For this reason we recommend regular cleaning Do not use a damp cloth to clean your hearing aids Always use a soft dry cloth Should your hearing...

Page 12: ... drying station of the type dry star UV 2 or dry go use this for drying Take note of the individual product instructions for further details Alternatively you can dry your hearing aids in the audifon pro care Drying Tub with an audifon Drying Capsule 7 2 Changing earwax protection filter Your hearing aids have protection filters to prevent earwax being deposited inside the receiver It is necessary...

Page 13: ...his does not eliminate the fault consult your hearing care professional who will be pleased to help you Note Malfunctions Your devices may be subject to interference from other electrical equipment despite their EMC compatible design If this occurs please consult your hearing care professional dry go The audifon dry go is the perfect solution for drying your devices when on trips or if out and abo...

Page 14: ...t explicitly approved can in the worst case lead to injuries Warning Risk of suffocation Batteries hearing aids and other small parts e g magnets may be swallowed For this reason these hearing aids are not intended for use by children under 36 months of age Never leave children unattended with your hearing aids Should a battery hearing aid or other small parts be accidentally swallowed please cons...

Page 15: ...other electrical equipment despite their EMC compatible design In this case move away from the source of interference Warning Electric shock Audio devices supplied with mains power must comply with IEC 60065 IEC 60601 or similar safety standards to ensure that they can be connected to your hearing aids without any risk to safety 9 2 Information about product safety Note Damage to hearing aid Heari...

Page 16: ...ic individual case Close supervision by a caregiver is recommended to ensure proper use of the hearing instruments and to avoid accidental swallowing of hearing instruments or parts thereof Note Leaking batteries can damage your hearing aid hearing aid If you do not intend to use your hearing aids for a long time remove the battery to increase its service lifespan to avoid leakage and to prevent c...

Page 17: ... Storage temperature must lie between 20 C and 60 C Remove battery for storage Store away from magnetic fields 13 ENVIRONMENTALLY COMPATIBLE DISPOSAL In accordance with European defaults used electrical and electronics devices may no more be given to the unsorted waste The symbol of the waste bin on wheels refers to the necessity of separate collection Please help with environmental protection and...

Page 18: ...earing care professional Date Hearing care professional 15 SERVICE Arrange for your hearing aids to be checked regularly by a hearing care professional Date Hearing care professional Date Hearing care professional Date Hearing care professional ...

Page 19: ... users can also return electronic waste to their hearing care professional for disposal Electronic equipment covered by Directive 2012 19 EU on waste and electrical equipment WEEE Consult instructions for use Indicates the need for the user to consult the instructions for use Humidity limitation Indicates the range of humidity to which the medical device can be safely exposed Temperature limit Ind...

Page 20: ...roper repair Therefore please always follow the safety and care instructions Proof of purchase must be provided as proof of warranty The date of purchase and the serial number must be clearly visible Warranty obligations will not result in any extension of the warranty period nor will they give rise to a new warranty period for the hearing aid The warranty period for built in spare parts ends at t...

Page 21: ...41 3040 Revision date 08 2021 High tech made in Germany audifon GmbH Co KG Werner von Siemens Straße 2 99625 Kölleda Germany www audifon com Telephone 49 3635 4056 590 Fax 49 3635 4056 589 Manufacturer contact audifon com ...