background image

The Omni

Hearing Aid 

Instruction Manual

312 Battery

Summary of Contents for Omni

Page 1: ...The Omni HearingAid InstructionManual 312Battery ...

Page 2: ...rt farther into your ear injuring your eardrum or ear canal possibly seriously Note If you remain concerned consult a professional If you try this device and continue to struggle with or remain concerned about your hearing you should consult with a hearing healthcare professional Note What you might expect when you start using a hearing aid A hearing aid can benefit many people with hearing loss H...

Page 3: ...aside a few minutes to review in order to get the most out of your custom tailored Audicus hearing aids Audicus is with you every step of the way Find more info and help at audicus com support And remember you re never on your own Reach out anytime for anything at all 917 999 0705 help audicus com ...

Page 4: ... case size 312 batteries 312 dome variety pack small medium large styles dependent on hearing loss carrying case cleaning brush audiowipes Getting Started page 8 Using The Omni page 20 Accessories Bluetooth page 28 Device Information page 36 Troubleshooting page 18 Contents ...

Page 5: ...in the tip dome grey hypoallergenic silicone cover on the receiver to hold in place comfortably 9 The battery door acts as the on off switch ON fully closed OFF partly open OFF fully open 312 zinc air brown tab IEC PR41 ANSI 7002ZD Low battery warning 2 beeps 30 mins remaining Battery size Turning on off Do not dispose of batteries in household trash Do not recharge batteries as this could result ...

Page 6: ...t the old battery 2 Remove the plastic tab from the new battery wait 2 3 minutes for the battery to activate 3 Line up the battery s plus sign flat side of the battery with the on the battery door 4 Close the battery door gently 5 The hearing aid will play a melody as it turns on Inserting a new battery 11 ...

Page 7: ...he bowl of your ear Handle your hearing aid with care Do not pull on or bend the wire as this may cause damage retention guard 13 Adding Removing the Retention Guard We recommend the retention guard for a more stable positioning of the receiver in the ear canal To add 1 Hold the receiver firmly in one hand with the receiver text e g 2M facing upwards In the other hand hold the retention guard at t...

Page 8: ...our hearing aid is programmed to you individually Adjustingto hearingaidsfullymaytake upto6weeks 1 You may hear sounds you haven t heard in years Sounds will be amplified and more distinguished e g leaves rustling running water your own voice Sensitivity to new sounds is normal and will go away with regular use 2 Find the right dome for your ear Your hearing aid ships with a size medium dome attac...

Page 9: ...nformation at audicus com adjust Remote adjustment requests may take up to 72 hours to process Any significant changes in your hearing loss or requests to modify your programs may require the device to be sent to Audicus for a full reprogramming 17 Ensure push notifications are enabled for the app When the remote adjustment is ready you will receive a notification on your phone Open the Hearing Re...

Page 10: ...lace dome and replace earwax guard See Replacing the dome and earwax guard Plugged microphone Clean device with cleaning brush If issue persists contact Audicus Receiver not inserted properly See page Putting on your hearing aid 19 Cause Remedy Two long beeps Low battery Replace battery Feedback whistling Hand or clothing near device Move hand clothing away from device Dome not inserted properly S...

Page 11: ...g loss your order may not include all dome styles Take some time to find which size dome is right for you The dome should fit snugly in your ear canal and inserted far enough to not be visible If missized or the wrong style you may hear feedback a squealing or whistling sound that can be resolved with a different dome size or style Order new domes at audicus com omni supplies Clean your domes regu...

Page 12: ... need to clean your devices more frequently Never use cleaning agents such as detergent soap alcohol or bleach to clean your hearing aid Do not submerge your hearing aid or rinse your hearing aid under water 23 Audicus Care All the products needed to care and maintain your device are available at audicus com supplies Audicus Care is the easiest way to get everything you need to maintain your Omni ...

Page 13: ...rder comes with a grey circular accessory which contains eight new earwax guards and is also the earwax guard removal tool 25 C To dispose of the used earwax guard first ensure chamber 1 is empty Then press the receiver in until it clicks this will remove the used earwax guard D Ensure the receiver is empty and a new earwax guard is visible in chamber 2 Press the empty receiver into chamber 2 and ...

Page 14: ...rces of high temperature Do not leave your hearing aid in direct sunlight or wear while using a hair dryer Keep hearing aids away from children and pets 27 Clean Care Repairs and Audicus Protect Your hearing aids come with a 24 month manufacturer s warranty Additional repairs may incur costs depending on the severity Accidents happen The Audicus Protect plan has you covered With Audicus Protect yo...

Page 15: ...e volume and programs with this small and discreet device The Remote Control uses a non rechargeable CR2032 battery 29 Partner Mic This small device can be worn by a conversation partner to stream their voice directly to your hearing aids wirelessly Small and discreet with a convenient clip the Partner Mic is ideal for busy environments such Order your Omni accessories at audicus com omni supplies...

Page 16: ... reconnect when in range of your phone This reconnection can take up to 2 minutes Hands free calls When paired phone calls are automatically transferred to your hearing aids Your voice is picked up by the hearing aid s microphones To accept an incoming call you will first hear a notification through the hearing aids The call can be accepted by a short press on the multi function button either UP o...

Page 17: ...phones work well with Bluetooth devices Follow these steps if you are having trouble con necting or experiencing poor audio with Bluetooth 1 Disconnect aids from remote app if installed Settings My Hearing Aids My Devices Forget Devices 2 Uninstall the Hearing Remote app if installed 3 Delete forget hearing aids from Bluetooth menu 4 Check for and install any updates on your phone 5 Disable enable...

Page 18: ...thout an app with any compatible Bluetooth devices For additional functionality control and remote adjustment you can use the optional smartphone app Note this app may not be compatible with all smartphones The free Hearing Remote app can be downloaded from the App Store iOS or Play Store Android Find links at audicus com app 35 ...

Page 19: ...ay long The best way to ensure better hearing is to practice listening with your hearing aid until you are able to wear it comfortably all day Generally infrequent use of the hearing aid does not provide you with the full benefit of amplification Your hearing aid will not restore normal hearing Hearing aids will not prevent or improve hearing impairment resulting from a physiological condition Hea...

Page 20: ...or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the device into an outlet on a circuit different from that to which the receiver is connected Consult the d...

Page 21: ...id is purchased 41 Following the medical evaluation the physician will give you a written statement that states that your hearing loss has been medically evaluated and that you may be considered a candidate for a hearing aid The physician will refer you to an audiologist or a hearing aid dispenser as appropriate for a hearing aid evaluation The audiologist or hearing aid dispenser will conduct a h...

Page 22: ... Pressure Level 90 OSPL90 dB SPL 111 114 Full on gain input 50 dB SPL 46 50 Total harmonic distortion at 500Hz 800Hz 1600Hz 3200Hz 1 5 2 0 2 0 1 0 Equivalent input noise at Reference Test Setting dB SPL 19 Latency ms 8 Frequency range Hz 100 8000 Typical battery life h 80 43 ...

Page 23: ...Rev22KD audicus com 917 999 0705 help audicus com ...