background image

M2DIS

User Manual

www.audac.eu

Summary of Contents for M2DIS

Page 1: ...M2DIS User Manual www audac eu ...

Page 2: ...2 ...

Page 3: ...8 Test signals 10 Sound settings 11 Settings screen 12 Input Configuration 13 Output Configuration 14 Global scene 14 Timer settings 16 Paging Volume 17 Priority settings 18 System configuration 19 Address settings 24 Password settings 25 Factory settings 26 Fiber settings 27 Amplifier Bridging 28 Notes 29 ...

Page 4: ...te the control and configuration functions of the matrix system without any external equipment This can be useful for direct access when the system is installed in a technical room where no external control devices are within reach or in case the system is not connected to a LAN network due to security reasons Touchscreen precautions Tap the touchscreen gently Never use force Don t use any sharp o...

Page 5: ... logging in with the user password you only get access to the basic functions of the main screen such as changing the volume and changing the mixing presets for a particular output The factory default password for user access is user After pressing the text field a keyboard screen will come up and the password can be entered After the password is entered press the OK button and you will be redirec...

Page 6: ...oggled from muted to unmuted by pressing it Assign names to output This option is only available if logged in as ADMINISTRATOR For a better overview of all outputs a name can be assigned to every output The names displayed are identical to the names entered in the web interface The name for the output can be changed by pressing and holding the name for 2 seconds After 2 seconds a keyboard screen w...

Page 7: ...is screen can be reached through Settings screen followed by output configuration screen Output settings This option is only available if logged in as ADMINISTRATOR By pressing the Settings button above a slider the Output Settings screen is displayed In this window you can select all input channels to be mixed for the selected output You can also select filters Save This option is only available ...

Page 8: ...ll show the info screen Output Settings This option is only available if logged in as ADMINISTRATOR By pressing the Settings button above a slider the Output Settings screen is displayed In this window you can select an input channel for the selected zone Input channel selection The screen gives an overview of all input channels that can be patched to the output zone You can select M2 inputs Wall ...

Page 9: ... default Here you can select the inputs you want to mix Click the Wall panel inputs button to select wall panel inputs Click the Fiber inputs button to select Fiber inputs Click the Line inputs button to select Line inputs To save click the apply scene or save as scene button ...

Page 10: ...als can be patched to any output zone When one of the test signals is selected Other will appear in the Input Selection box on the main screen Select white noise to route white noise to the output zone Select pink noise to route pink noise to the output zone Select Sine Generator to route a sine wave to the output zone The frequency of the sine wave can be changed by the up and down arrows ...

Page 11: ...een you can control the value of bass and treble for this output This screen shows two faders One to control the bass low tones which can be adjusted from 9 to 9 dB The other controls the treble high tones and can also be adjusted from 9 to 9 dB ...

Page 12: ...xt settings can be changed Input configuration Output configuration Global scenes Timer settings Paging volume Priority settings System configuration Fiber settings Amplifier Bridging If you want to change some settings just click on the corresponding icon When you are done with configurating the M2 you need to press the save configuration button If you don t the settings will be lost at restartin...

Page 13: ...ows you to change the line and mic settings for this input For both Line and Mic you can set the gain apply ALC automatic Level Control apply several different filters or apply a 3 or 7 band equalizer by clicking the corresponding button Also the input can be muted toggled between mono and stereo and phantom power can be enabled ...

Page 14: ... filters apply a 3 or 7 band equalizer set quick menu settings set output linking settings and set talkover settings by clicking the corresponding button Also the output can be toggled between mono and stereo or toggle between Single ended and Balanced Even antiphase and a delay time can be set for a certain output For more info on these settings please refer to the M2 User Manual Settings Global ...

Page 15: ...s you can see you can set an input and volume for every output a trigger can also be set When the trigger occurs then this global scene will be enforced allowing you to set global scenes for all kinds of things from commercial messages to the fire alarm To keep things clear you can give each of the eight scenes a name ...

Page 16: ...ck the action that needs to happen when the timerevent takes place Adjust the variables of this action to your desires and specify a day or date when the action needs to be executed Now click the Add button and everything will be saved For more information about this screen please refer to the M2 user manual ...

Page 17: ... Paging Volume In this window the volume for all outputs can be set to a value you see fit for paging For every output you can set the paging volume and choose if the relay for this ouput should be switched or not ...

Page 18: ...g first choose a channel on which the M2 will trigger your setting Now an input should be chosen You can select every output to which the input should be routed For every output it is possible to set volume and toggle relay position For more info about priority settings please refer to the M2 user manual ...

Page 19: ...19 System configuration Time settings In this window the time and date of the M2 can be set This can be done by selecting the values from a dropdown list Press Set Clock to set time and date ...

Page 20: ...Panel brightness Sets the brightness of the backlight Auto Logoff When enabled the system logs off after some time of no activity The administrator has to log on again Push Logoff time to change the time Limited control When enabled there is no logon screen At start up the main screen is shown The user can only change volume and mute For other functions the password will be asked ...

Page 21: ...ime Update software With this button the firmware of the display unit will be updated not the firmware of the M2 The software can be updated by placing a USB memory stick in the USB port at the rear side of the display unit and holding the Update software button for 3 seconds After 3 seconds an update screen appears and the system starts updating When finished updating the display unit restarts an...

Page 22: ...to be touched three times in a row to calibrate the touchscreen correctly To make an accurate calibration it should be touched exactly at the center position of the cross ATTENTION Don t use any sharp object to tap the touchscreen Don t use a pen but only use your fingertips or stylus especially meant for use with touchscreens The use of sharp objects can cause permanent damage to the touchscreen ...

Page 23: ...ed to the USB port at the back side of the display unit this indicator should also be green The dimming of the backlight can be tested by moving the slider The touchscreen can be tested by making a drawing in the white field Use the Clear button to erase the field Use the Update software button to update the software of the M2DIS Use the Calibration button to calibrate the touchscreen Use the BACK...

Page 24: ...only one M2 is available the default address can be left to its default value When two or more M2 s are cascaded through the fiber interconnection bus they need to have a unique address The first M2 starts with address 001 and every subsequent M2 should be assigned an address with a higher value Click the OK button to confirm the address settings ...

Page 25: ...or the User password can be changed To change the password enter the old password in the provided field and enter the new password twice in the provided fields After this all is completed push the OK button When the old password is correct and the new password filled in in both fields match the old password will be changed into the new password The factory default password for Administrator is M2 ...

Page 26: ...his button It will recall the ORIGINAL factory settings It does not recall the previously saved settings but it recalls the original factory setting and the previous made settings will be lost Click the OK button to reset the settings to factory default ...

Page 27: ... managed optional For every of the eight fiber channels you can set an input to link with other M2 or R2 units or pass through to take an input from a M2 or R2 unit and pass it through to an other M2 or R2 unit For more info on fiber settings please refer to the M2 user manual ...

Page 28: ...indow you can select one or more outputs to be bridged Select the output channels you want to bridge Bridging an output will result in a mono output with double power Note This will only have effect if the optional power amp kit is installed ...

Page 29: ...29 Notes ...

Page 30: ...30 Notes ...

Page 31: ...31 Notes ...

Page 32: ...32 Notes ...

Reviews: