SYSTEM DESIGN
710-14888-00C EMX4i User Manual
23
Environmental
Operating temperature ................ -10 ˚C~60 ˚C, above 40 ˚C with derating
Storage temperature .............................................................. -25 °C~+ 60 °C
Operating Altitude ........................... 0~1000 m, above 1000 m with derating
Humidity ............................................................... 5%~95% Relative Humidity
Pollution degree ................................................................ Pollution Degree 3
Vibration .................................................................................... IEC 60068-2-6
Protection
EMX4i-0024B~EMX4i-0135B .............................................................. IP20
EMX4i-0184B~EMX4i-0580B .............................................................. IP00
Heat dissipation
During Start .................................................................. 4.5 watts per ampere
During Run
EMX4i-0024B~EMX4i-0052B ........................................ ≤ 35 watts approx
EMX4i-0064B~EMX4i-0135B ........................................ ≤ 50 watts approx
EMX4i-0184B~EMX4i-0250B ...................................... ≤ 120 watts approx
EMX4i-0352B~EMX4i-0580B ...................................... ≤ 140 watts approx
Motor Overload Protection
Default: The default settings of parameters 1D, 1E and 1F provide Motor Overload
Protection: Class 10, Trip Current 105% of FLA (full load amperage) or equivalent.
Certification
CCC ................................................................................................... GB 14048.6
CE .................................................................................................... EN 60947-4-2
C-UL ...................................................................................... C22.2 Nº 60947-4-2
UL ..................................................................................................... UL 60947-4-2
Marine
Lloyds ................................................... Lloyds Marine No 1 Specification
ABS .................................................................... Steel Vessels Rules 2010
RCM ......................................................................................... IEC 60947-4-2
Operational life (internal bypass contacts)
.......................................................................................... 100 000 operations
3.16
Disposal Instructions
Equipment containing electrical components may not be
disposed of together with domestic waste.
It must be collected separately as electrical and electronic waste
according to local and currently valid legislation.