User I/O Tab
Figure 10-19 User I/O
➢
DI and DO are general digital I/O with a total of 16 inputs and 16 outputs that can be used for direct
drive relays and other electrical equipment.
➢
Analog input is used to display the voltage of the external sensor. There are 4 analog input signals:
VI0, VI1, VI2 and VI3, the range is 0V ~ +10V, and the accuracy is ± 1%.
➢
Analog output is used to display the voltage / current value of the output of the interface board. There
are four analog output signals: VO0, VO1, CO0 and CO1, respectively VO0, VO1 output voltage,
CO0, CO1 output current.
➢
output IO control: select the IO, and then enter the corresponding value in the text box, where DO
have 0 and 1 two states, AO: the voltage output range of 0V ~ +10 V, the current output range of 0mA
~ 20mA (recommended input 4mA ~ 20mA current value), click
【
Send
】
button, the corresponding
IO is set to the default value.
Tool I/O Tab
This section introduces the setting of I/O interface provided by the teach pendant. For the detailed
description of the interface, please refer to electrical interface Manual. I/O settings panel includes tool I/O
tab, controller I/O tab and PLC I/O tab.
Summary of Contents for AUBO-i10
Page 1: ...USER MANUAL AUBO i10 CB4 Please read this manual carefully before using the product...
Page 2: ......
Page 10: ...V4 5 2015 2019 AUBO All rights reserved vi...
Page 26: ...V4 5 2015 2019 AUBO All rights reserved 22...
Page 44: ...V4 5 2015 2019 AUBO All rights reserved 40...
Page 56: ...V4 5 2015 2019 AUBO All rights reserved 52...
Page 87: ...V4 5 2015 2019 AUBO All rights reserved 83...
Page 127: ...V4 5 2015 2019 AUBO All rights reserved 123...
Page 161: ...V4 5 2015 2019 AUBO All rights reserved 157 Figure 11 43 script file editor...
Page 179: ......