background image

 

1

 

Operation Instruction Manual 

WSD-1203CPH  

Programmable PID Temperature Controller with Dual Probe

*

 

Version 1.4 

Auber Instruments 

5755 North Point Parkway, Suite 99 

Alpharetta, GA 30022 

770-569-8420 

www.auberins.com 

July, 2013 

Introduction 

Thank you for purchasing the Auber WS series temperature controller. We sincerely 
appreciate your decision and trust that our machine will meet your expectations in both 
the quality of the result and the value of our product. While we are delighted that you may 
be anxious to operate the controller for your project, a few minutes of your time reading 
through this manual will only serve to enhance your experience in the months and years 
ahead. In particular, we urge you to read through the safety warnings below. Although 
this plug-and-play controller is very easy to operate, the process involves high 
temperature and high wattage appliances, and your safety is paramount. 

 SAFETY WARNINGS 

 

  This controller is designed to be used only with devices that have limited power 

and their own thermal cut off protection, such as a thermostat or thermal fuse in 
case of controller failure. 

  Do not place any objects on top of the controller surface as it is used to vent 

excess heat during its operation.   

  The maximum electric current this controller can handle is 12 ampere. For 120 

volt AC in US and Canada, this limits the heater power to 1440 watts. 

 

  Always place the sensor in the controlled subject when the controller is on. Before 

turning on the controller, please make sure the sensor is placed inside the 
container to be controlled. Leaving the sensor outside of the solution will form an 
open loop operation, and the controller will assume the temperature is low even if 
the controlled subject is already very hot. The controller will provide full power to 
the heater which will not only overheat the controller, but also damage your 

                                                        

*

 Patent pending 

Summary of Contents for WSD-1203CPH

Page 1: ...h temperature and high wattage appliances and your safety is paramount SAFETY WARNINGS This controller is designed to be used only with devices that have limited power and their own thermal cut off pr...

Page 2: ...nel 1 TEMP1 Left window During normal operation it displays the temperature values of probe 1 When the high or low limit alarm of probe 1 is on this window will flash between the alarm type AH1or AL1...

Page 3: ...nd confirming various actions taken 7 Key To decrement displayed values when controller is in the parameter setting mode During normal operation press it to cancel the alarm 8 Key To increment display...

Page 4: ...s to be inserted into the meat Figure 3 Sensor position Left the sensor should be placed close to the food but high enough so that it does not touch the food Right hold the sensor in place by a piece...

Page 5: ...4 Connection between the controller and Bradley Original Smoke generator c Connecting the controller output to the Bradley Smoker Tower with the power cord that came with the Auber Controller Figure 5...

Page 6: ...6 Figure 6 Back view Figure 7 Connection between the controller and smoker...

Page 7: ...onnected between the generator and tower Then connect the controller heat output to the smoke tower with the cable supplied with the controller Figure 8 Connection without controlling the smoker gener...

Page 8: ...If the time is set too short the temperature may not be able to reach the current step temperature setting before it jumps to the next step The time unit is in hours with 0 1 hour 6 minute resolution...

Page 9: ...ing END on both windows and turn on the beeping alarm to notify you that cooking is finished Table 1 Initial program setting Step Temp F Step F or T Step value C01 120 E01 t t01 2 0 C02 190 E02 F F02...

Page 10: ...difficult to read when sun light is directly shined to its surface Users should also avoid exposing the controller to water and rain which could damage the controller b Low temperature control The con...

Page 11: ...ogrammed It will turns off when program goes to the next step e g When R1 2 and R2 4 the smoker generator will be on during step 2 and 4 R1 0 or R2 0 means that R1 or R2 will not do anything to the sm...

Page 12: ...o the temperature when meat is ready It will let you know when it is done Then you can move the probe to the second thinnest pieces and so on To use this feature you can set the ending criteria to tim...