background image

 

 

Quick Guide for WS-1211GPH 

Programmable Precision PID Temperature Controller 

Version 1.3 (June, 2021) 

 

Auber Instruments 

5755 North Point Parkway, Suite 99 

Alpharetta, GA 30022 

770-569-8420 

www.auberins.com 

 

Introduction 

Thank you for shopping the Auber WS series temperature controller. We sincerely appreciate your 
decision and trust that our controller will meet your expectations in both the quality of the result 
and the  value  of  the  product. While we are  delighted  that  you  may  be  anxious  to  operate the 
controller, please still spend a few minutes reading through this manual because this will serve to 
enhance  your  experience  in  the  months  and  years  ahead.  In  particular,  we  urge  you  to  read 
through the safety warnings below. Although this plug-and-play controller is very easy to use, the 
process involves high temperature and high wattage appliances and your safety is paramount. 

  SAFETY WARNINGS 

 

 

This controller is designed only to be used with limited-power device and paring thermal 
cutoff protection such as a thermostat or thermal.   

 

Do not place any objects on the top of controller surface because that may prevent venting 
excess heat during its operation.   

 

The controller can handle a maximum current up to 12 Ampere. For 120 VAC in US or 
Canada, this limits the heater power to 1440 watts. Due to its compact size and the splash 
proof design for kitchen applications, the controller has a limited ability to dissipate the 
heat generated by the internal solid state relay during the initial heat up. The initial full 
power heat up process cannot be more than 90 minutes. If you system need take longer 
time to warm up, please read Appendix 1 “Managing the heat generated by the controller

” 

 

Always place the temperature sensor in your controlled subject (like your smoker) 
before  you  turn  on  your  controller.

  Leaving  the  temperature  sensor  outside  of  your 

controlled  subject  will  form  an  open  loop  operation. 

If  the  sensor  is  left  outside

,  the 

controller will assume the temperature is low even if the controlled subject is already very 

Summary of Contents for WS-1211GPH

Page 1: ...s designed only to be used with limited power device and paring thermal cutoff protection such as a thermostat or thermal Do not place any objects on the top of controller surface because that may pre...

Page 2: ...nly Using it to control a not recommended device can be dangerous and even cause fire Auber Instruments is not liable for damages caused by misuse of the controller If you are not sure the controller...

Page 3: ...4 Key To increase the value at parameter setting mode toggle LED display between the current temperature and the current step number at normal operating mode 5 Key To decrease the value at parameter...

Page 4: ...cted to the power strip by the 16 AWG power cord supplied blue arrows The generator is connected to the power strip by the power cord from Bradley green arrows The controller output is connected to th...

Page 5: ...or by the power jumper cord provided by the Bradley blue arrows It is the cord that used to connect the generator to smoker The controller output is connected to the smoker by the power cord red arrow...

Page 6: ...r t is displayed as the symbol T Time is defined as the duration between the last step and the next step Please make sure the time is long enough for the heater to heat up the oven If the time is set...

Page 7: ...me in the current step using the Time or key Please see the flow chart in Figure 5 080 10 P 2 Time Total operating time since power up Press once Press once Operating time on current step P 1 Press on...

Page 8: ...s vide cooking For details on how to access these parameters please check section 5 of the main instruction manual 5 1 The first group of parameter is related to the control performance They need to b...

Page 9: ...These recipes can be stored in the memory of the controller even when it is powered off You can overwrite the exist recipe with a new one For details on how to access these parameters please check sec...

Page 10: ...ecall a recipe press and hold SET key for 3 seconds until the Parameter Window displays LOCK Release the SET The display will show 0 Use and keys to adjust the display to 3 and press SET The display w...

Page 11: ...e and then set C 1 150 press set again to confirm and exit The controller will go back to the normal operating mode and start running on this single step program To store current program back to recip...

Page 12: ...show 0 then Use key to adjust the number to 666 and press SET key again to confirm The display will show as lnlE then it will show as off Press key once to change off to on Press SET key to confirm fa...