background image

  AUBER INSTRUMENTS

    

 

 

     

 

 

 

             

WWW.AUBERINS.COM  

 

2019.08                                                                                                                                                                                                          P1/4

 

TD120-W WIRELESS TEMPERATURE CONTROLLER 

   INSTRUCTION MANUAL   

Version 1.0 (August, 2019)

 

1. Overview 

This  temperature  controller  contains  one  temperature  probe  and  two 

independent  outputs.  One  output  is  for  cooling  device  such  as 
refrigerator and the other one is for heating device. It can be used for 
applications  such  as  beer  fermentation  or  convert  a  refrigerator  to 

kegerator. By using both cooling and heating devices, the refrigerator 
can be controlled at specific temperature regardless in hot summer or 
cold winter. 

This controller is a plug-and-play controller. No wiring is needed for the 

heater or cooler.  Both heating and cooling control modes are simple 
on/off control, similar to a mechanical thermostat but with much higher 

precision due to adjustable hysteresis band, precise sensor and digital 
readout.    Anti-short  function  is  provided  for  cooling  to  protect  the 
compressor from being turned on with high pressure Freon. 

Different operation temperature ranges of the two outputs can be set 

separately.  Once  the  cooling  range  is  set,  the  controller  program  will 
automatically  limit  the  heating  range  to  prevent  both  heating  and 
cooling from being turned on at the same time. 

A digital silicon band gap sensor is used. The advantage is being much 
more reliable in moisture environment than thermistor sensor. It can be 
immersed  over  extended  period  of  time.  It  also  has  a  more  uniform 
accuracy over an entire specified temperature range. 

Reversed  logic  function  has  been  added  to  this  model,  which  can 
activate the  one single output  when temperature is in a range set by 
HSP  (heating  setpoint)  and  CSP  (cooling  setpoint).  For  details,  see 
note 7 on page 3.  

 
2. Specification

 

Temperature  

Control Range 

-50 ~ 105° C, -58 ~ 221° F 

Temperature 

Resolution 

0.1 ° C (between -9.9 ~ 99° C) 

1 ° C (between -50 ~ -10° C, 100 ~ 120° C) 

0.1 ° F (between -9.9 ~ 99.9° F) 

1 ° F (between -58 ~ -10° F, 100 ~ 248° F) 

Temperature Accuracy 

0.5 ° C or 0.9 ° F 

Temperature Control 

Mode 

On/Off Control. Heating and Cooling 

Temperature Control 

Output 

10A, 120V or 240V AC* 

Audio Alarm 

High and Low Limit 

Sensor Type 

Silicon Band Gap Sensor 

Ambient Temperature 

0 ~ 120° F (-20 ~ 50° C) 

Dimension 

91 x 140 x 46 mm 

Input Power 

85 ~ 242V AC, 50Hz/60Hz 

Power Cable Length 

3 ft (1m) 

Warranty 

1 Year for the controller 

 
*: Either the heating or the cooling device is limited to 10 Amps. The output voltage is the 

same as the input voltage.  When the controller is plugged into 120V AC, the output will 
be 120V AC. If the controller is connected to 240V AC, the output will be 240V AC also. 

 

3. Front Panel 

Up Key
Dn Key, Mute Alarm

Set Key

Cooling Device

Socket

Heating Device
Socket

Heating device
On Indicator

Cooling Device 

On Indicator

Measured

Temperature

Sensor Socket

WIFI Indicator

Figure 1. Front Panel 

4. WIFI Function

 

To reset the WIFI function of this controller, push down and hold SET 

key  and  down  arrow  key  at  same  time  for  about  3s.  Then  WIFI 
indicator will be fast blinking (4 Hz). It indicates this controller is waiting 

for  new  setup  now.  After  the  controller  is  setup  to  your  phone 
successfully,  the  WIFI  indicator  will  be  OFF  at  most  of  the  time.  For 
details, see supplementary manual for details.  

 
5. Setup Flow Chart 

When the controller is powered on, it will display the measured 

temperature. The controller will keep running according to the saved 
setting. If the temperature sensor is shorted/disconnected, the 

controller will display “Err”. Please see Figure 2 for the flow chart to set 

the parameters. 
 

SET

 6 8

.

9

SET

 CSP

 HSP

Measured 

Temp

Cooling 
Set Point

Heating 
Set Point

SET

  

Figure 2. Flow Chart Part 1 

 
 

Instruction Manual

 

 

Summary of Contents for TD120-W

Page 1: ...note 7 on page 3 2 Specification Temperature Control Range 50 105 C 58 221 F Temperature Resolution 0 1 C between 9 9 99 C 1 C between 50 10 C 100 120 C 0 1 F between 9 9 99 9 F 1 F between 58 10 F 100 248 F Temperature Accuracy 0 5 C or 0 9 F Temperature Control Mode On Off Control Heating and Cooling Temperature Control Output 10A 120V or 240V AC Audio Alarm High and Low Limit Sensor Type Silico...

Page 2: ...Symbol Description Setting range Initial Note Menu for set points Figure 2 CSP CSP Cooling Set Point 58 248ºF 50 125ºC 67 0 1 HSP HSP Heating Set Point 58 CSPºF 50 CSPºC 62 0 Menu for parameters Figure 3 AH AH Alarm High Limit 58 248ºF 50 125ºC 95 0 2 AL AL Alarm Low Limit 58 AHºF 50 AHºC 34 CdF CDF Cooling Differential 0 50 0ºF 3 0 1 HdF HDF Heating Differential 0 50 0ºF 0 0 AS AS Cooling Antisho...

Page 3: ...erature if the unit displays 37ºF when the actual temperature is 32ºF setting parameter oFS 5 will make the controller display 32ºF Note 6 C F determines the temperature unit It can be set to C Celsius C or F Fahrenheit F Note 7 LGC Control Logic advanced feature This parameter is used to change the current control logic mode Three modes are available NOR normal control logic default R C reverse l...

Page 4: ...7 How to install the sensor to the unit The connector of sensor contains a slot for fitting pin connection It also has a spring lock to prevent disconnections from accidental pulling on the cable To install the sensor to the controller 1 identify the key on the male connector Figure 5 a and the notch on the female connector Figure 5 b 2 hold the tail of the female connector align the notch and the...

Reviews: