Auber Instruments EZboil DSPR320 Instruction Manual Download Page 1

  AUBER INSTRUMENTS

    

 

 

     

 

 

 

             

WWW.AUBERINS.COM  

 

2018.08                                                                                                                                                                                                          P1/11

 

                 

                                                                           

Instruction Manual for EZBoil

®

 DSPR320 

Version 1.0 (August, 2018) 

 

 

Caution

  

 

This controller is intended to control equipment under normal operating 

conditions. Failure or malfunction of the controller may lead to abnormal 
operating conditions, which result in personal injury or damage to the equipment 
or other property. Devices (limit or safety controls) or systems (alarm or 
supervisory) intended to warn of or protect against failure or malfunction of the 
controller must be incorporated into and maintained as part of the control system. 

 

Installing the rubber gasket supplied will protect the controller front panel from 

dust and water splash (IP54 rating). Additional protection is needed  for higher 
IP rating. 

 

This controller carries a 90-day warranty. This warranty is limited to the 
controller only. 

 
 

1.

 

Specifications 

Table 1. Specs of DSPR320. 

Input type 

RTD (Resistance Temperature Detector): PT100 

Accuracy 

± 0.2% of full scale 

Sensor input range 

0°F ~ 932°F, -17°C ~ 500°C 

Response time 

 0.5 s 

Display resolution 

1°C or °F 

Control mode 

temperature, power 

Program step 

Up to 9 steps in each mode 

Timer range 

00 H 00 M to 99 H 00 M 

Main output 

12 VDC for solid state relay 

Relay output 

3 A for resistive load. 1 A for inductive load 

Number of relays 

2  

Power supply 

85 V ~ 260 V AC / 50 ~ 60 Hz 

Power consumption 

 5 Watt 

Working ambient 
temperature 

0ºC ~ 50ºC, 32ºF ~ 122ºF 

Dimensions 

48 x 48 x 100 mm (W x H x D, from the front panel to the back) 

Mounting cutout 

45 x 45 mm 

 
 

2.

 

Front Panel 

 

8

5

4

1

2

3

7

6

9

10

 

 

Figure 1. The front panel of DSPR320. 

 
 

2.1.

 

Display 

Table 2. Front panel display.  

Name 

Descriptions 

Top Display  

 

Temperature reading and step-timer. 

Parameter names.  

Bottom Display 

 

Set value, step number, and program 
status. 

Parameter values.   

AL1 Indicator (red) 

 

Light up when Relay 1 (AL1) pulls in.  

AL2 Indicator (red) 

Light up when Relay 2 (AL2) pulls in.  

MASH Mode 
Indicator (yellow) 

 

Light up when controller is in MASH 
mode.  

Output Indicator 
(green) 

 

Light up when the controller is sending 
control signal to the SSRs. When it 
flashes, the percentage of time of it 
being lit up indicates the percentage of 
power that is being sent to the SSRs. 

 
 

2.2.

 

Key Functions 

Table 3. Key functions 

Key 

Action 

Functions 

Knob 

Short press 

 

Press the knob to bring up the 
Quick Access Menu. 

 

Press the knob to select a 
parameter or to save the 
parameter value.  

Long press 

 

Press and hold the knob 3 
seconds to bring up the Main 
Menu. 

Rotate 

 

Rotate the knob to browse and 
change parameter values. 

RUN 

Short press 

 

Start the program. 

 

Resume the timer if timer is 
paused.  

 

Mute the on-board buzzer and/or 
cancel the relay action if 
temperature alarms are triggered.  

10 

HOLD 
/STOP 

Short press 

 

Pause the timer. 

 

Hold it down for 2 seconds to stop 
the program.  

Long press 

 

End the program and stop all 
outputs.  

Combination 

RUN 

KNOB 

Hold

 

down the 
RUN key 
and press 
the knob

 

 

Go back to the previous 
parameter in the menu list.  

 
 

3.

 

Wiring Terminals 

 
The pin assignment of the back terminals of DSPR320 is shown in Figure 2 and 
the descriptions of each terminal are given in the table below.  

Instruction Manual

 

Summary of Contents for EZboil DSPR320

Page 1: ...nt panel to the back Mounting cutout 45 x 45 mm 2 Front Panel 8 5 4 1 2 3 7 6 9 10 Figure 1 The front panel of DSPR320 2 1 Display Table 2 Front panel display Name Descriptions 1 Top Display Temperatu...

Page 2: ...e menu structure of DSPR320 and how to access the menu Table 5 Menu structure of DSPR320 Quick Access Menu Short press the knob to bring up the Quick Menu rotate the knob to browse different options p...

Page 3: ...how to pause the timer 0 0 4 5 m 1 HOLD 1 5 0 HOLD Press RUN m 1 RUN Press Figure 11 Operations to pause and to resume the step timer When the timer is paused from the key pad a dot will also appear i...

Page 4: ...consist of the set value and the step timer The step timer only starts counting when the temperature has reached a pre defined timer start point see section 5 6 for details 5 4 Ramp Sections In DSPR3...

Page 5: ...escription SKIP Bypass this step HOLD Hold the program at the current step Press RUN key to continue to the next step END End the program CONT End the MASH Program and continue to execute the first st...

Page 6: ...ss the knob shortly When the controller is not executing any program i e the controller is at the END or the STOP status press the knob will bring up the RST function If a program has been started pre...

Page 7: ...emperature Note 4 mOUT acceleration output power for mashing steps determines the maximum output power can be sent during the acceleration stage of heating up the water or wort toward the set temperat...

Page 8: ...e previous step has ended and before the next step starts A ramp section is essentially a section between two steps when step timer isn t counting time Note 1 5 HEAT Relay will be activated during the...

Page 9: ...han dH SV the alarm relay will be activated it will be deactivated when temperature drops below dH SV HY Similarly when the temperature is lower than SV dL the alarm relay will be activated it will be...

Page 10: ...rewing in a BIAB setup In this example a DSPR320 is used to control the heater in a BIAB kettle The Relay 1 will be used to control the wort circulation pump during mashing and the Relay 2 will be use...

Page 11: ...he Relay 1 pin 1 and 2 on DSPR320 to control a R30A 120V coil relay which supplies power to a 15A socket End Auber Instruments 5755 North Point Parkway Suite 99 Alpharetta GA 30022 www auberins com Em...