![Auber Instruments EZboil DSPR320 Instruction Manual Download Page 1](http://html1.mh-extra.com/html/auber-instruments/ezboil-dspr320/ezboil-dspr320_instruction-manual_3006752001.webp)
AUBER INSTRUMENTS
WWW.AUBERINS.COM
2018.08 P1/11
Instruction Manual for EZBoil
®
DSPR320
Version 1.0 (August, 2018)
Caution
This controller is intended to control equipment under normal operating
conditions. Failure or malfunction of the controller may lead to abnormal
operating conditions, which result in personal injury or damage to the equipment
or other property. Devices (limit or safety controls) or systems (alarm or
supervisory) intended to warn of or protect against failure or malfunction of the
controller must be incorporated into and maintained as part of the control system.
Installing the rubber gasket supplied will protect the controller front panel from
dust and water splash (IP54 rating). Additional protection is needed for higher
IP rating.
This controller carries a 90-day warranty. This warranty is limited to the
controller only.
1.
Specifications
Table 1. Specs of DSPR320.
Input type
RTD (Resistance Temperature Detector): PT100
Accuracy
± 0.2% of full scale
Sensor input range
0°F ~ 932°F, -17°C ~ 500°C
Response time
≤
0.5 s
Display resolution
1°C or °F
Control mode
temperature, power
Program step
Up to 9 steps in each mode
Timer range
00 H 00 M to 99 H 00 M
Main output
12 VDC for solid state relay
Relay output
3 A for resistive load. 1 A for inductive load
Number of relays
2
Power supply
85 V ~ 260 V AC / 50 ~ 60 Hz
Power consumption
≤
5 Watt
Working ambient
temperature
0ºC ~ 50ºC, 32ºF ~ 122ºF
Dimensions
48 x 48 x 100 mm (W x H x D, from the front panel to the back)
Mounting cutout
45 x 45 mm
2.
Front Panel
8
5
4
1
2
3
7
6
9
10
Figure 1. The front panel of DSPR320.
2.1.
Display
Table 2. Front panel display.
#
Name
Descriptions
1
Top Display
Temperature reading and step-timer.
Parameter names.
2
Bottom Display
Set value, step number, and program
status.
Parameter values.
3
AL1 Indicator (red)
Light up when Relay 1 (AL1) pulls in.
4
AL2 Indicator (red)
Light up when Relay 2 (AL2) pulls in.
5
MASH Mode
Indicator (yellow)
Light up when controller is in MASH
mode.
6
Output Indicator
(green)
Light up when the controller is sending
control signal to the SSRs. When it
flashes, the percentage of time of it
being lit up indicates the percentage of
power that is being sent to the SSRs.
2.2.
Key Functions
Table 3. Key functions
#
Key
Action
Functions
8
Knob
Short press
Press the knob to bring up the
Quick Access Menu.
Press the knob to select a
parameter or to save the
parameter value.
Long press
Press and hold the knob 3
seconds to bring up the Main
Menu.
Rotate
Rotate the knob to browse and
change parameter values.
9
RUN
Short press
Start the program.
Resume the timer if timer is
paused.
Mute the on-board buzzer and/or
cancel the relay action if
temperature alarms are triggered.
10
HOLD
/STOP
Short press
Pause the timer.
Hold it down for 2 seconds to stop
the program.
Long press
End the program and stop all
outputs.
Combination
RUN
+
KNOB
Hold
down the
RUN key
and press
the knob
Go back to the previous
parameter in the menu list.
3.
Wiring Terminals
The pin assignment of the back terminals of DSPR320 is shown in Figure 2 and
the descriptions of each terminal are given in the table below.
Instruction Manual