2017.03                                                                                                                                                                                                          P1/9

 

                 

                                                                                                                          

EZboil, Power Regulator for Boiling Process Automation DSPR120 

Version 1.2 (Mar, 2017) 

 

 

Caution

  

 

This  controller  is  intended  to  control  equipment  under  normal  operating 
conditions.  Failure  or  malfunction  of  the  controller  may  lead  to  abnormal 
operating  conditions,  which  result  in  personal  injury  or  damage  to  the 
equipment  or  other  property.  Devices  (limit  or  safety  controls)  or  systems 
(alarm  or  supervisory)  intended  to  warn  of  or  protect  against  failure  or 
malfunction of the controller must be incorporated into and maintained as part 
of the control system. 

 

Installing the rubber gasket supplied will protect the controller front panel from 
dust and water splash (IP54 rating). Additional protection is needed  for higher 
IP rating. 

 

This  controller  carries  a  90-day  warranty.  This  warranty  is  limited  to  the 
controller only. 

 

1.

 

Specifications 

Input type 

RTD (Resistance Temperature Detector): Pt100 

Accuracy 

±  0.2% full scale 

Temperature 
range 

-328° F ~ +932° F, -200° C ~ +500° C 

Response time 

 0.5s  

Display 
resolution 

1° C or ° F 

Control mode 

Mashing, Boiling 

Alarm function 

Process high alarm 

Power supply 

85~260VAC/50~60Hz 

Power 
consumption 

 5 Watt 

Working Ambient 
temperature 

0~50ºC, 32~122ºF 

Dimension 

48 x 48 x 100 mm (W x H x D, from the front panel to 
the back) 

Mounting cutout 

45 x 45 mm 

 

2.

 

Front Panel 

3

4

5

1

2

6

 

Figure 1. The front panel of EZboil 

1). Top display.

 This display indicates the temperature sensor read out value. 

When timer is activated, it will show time and temperature alternately. 

2). Bottom display.

 In boiling mode, this display will show the percentage of 

power being sent to the external SSR after the initial heat up phase. In mashing 
control mode, this display will show the set temperature. 

3). Rotary switch (knob).

 Turn it clockwise to increase the output power (or 

selected parameter value); turn it counter-clockwise to reduce the output power 
(or selected parameter value). Press it briefly to reset the timer (if enabled) and 
to switch between mashing and boiling mode. Press and hold it for 5 seconds to 
enter parameter settings menu. Please see section 6 for details. 

4). Output indicator (OUT).

 This green LED light is synchronized with output. It 

shows how much power the regulator is sending out (as a 12VDC control signal 
pulse through terminal 6 and 7). When it is on solid, the output is 100% on. When 
it  is  off,  there  should  be  no  output.  When  it  is  flashing,  the  frequency  of  the 
flashing is an indication of high or low power output. Higher frequency means 
higher power output.  

5).  Mashing  mode  indicator  (MASH). 

This  yellow  LED  light  indicates  the 

operation mode of the controller. When it is on, controller is in mashing mode; 
when it is off, controller is in boiling mode.  

6). Temperature setting adjusting indicator.

 This is the small dot at the lower 

right corner. In mashing mode, when temperature set point is  adjusted, it will 
start  to  flash.  It  reminds  you  that  you  need  to  press  the  knob  to  confirm  the 
change. Otherwise, the temperature setting will return back in 2 seconds after 
you stop the adjustment.  
 

3.

 

Wiring Terminals 

The pin assignment of the back terminals of DSPR120 is shown in Figure 2.  

1
2
3

13 14 6

7
8
9

10

4
5

AC

85~260V

SSR

+

-

RTD

R

R

W

 

Figure 2. Terminal assignments of DSPR120.  

 

3.1 Sensor connection 

DSPR120 only accepts Pt100 RTD temperature sensor. For a three-wire RTD 
with  standard  DIN  color  code,  the  two  red  wires  should  be  connected  to  the 
terminals 3 and 4. The white wire should be connected to terminal 5. For a two-
wire RTD, the wires should be connected to terminals  4 and 5. Jump  a wire 
between terminals 3 and 4.  
 

3.2 Power to the controller 

The power cables should be connected to terminals 9 and 10. Polarity does not 
matter. It can be powered by 85-260V AC power source. Neither a transformer 
nor jumper is needed to wire it up. For the consistent with the wiring example 
described later, we suggest you connect the hot wire to terminal 10 and neutral 
to 9. 
 

3.3 SSR output connection 

The  SSR  control  output  of  the  DSPR110  provides  a  12V  DC  signal  that  can 
control up to 5 SSRs in parallel. Connect terminal 7 to the positive pole of the 
SSR (terminal 3 on 

Auber’s SSR

s). Connect terminal 6 to the negative pole of 

the SSR (terminal 4 on Auber

’s

 SSRs). Please make sure the SSR is installed 

on the heat sink with proper current rating. 
 

Instruction Manual

 

 

Summary of Contents for EZboil DSPR120

Page 1: ...rameter settings menu Please see section 6 for details 4 Output indicator OUT This green LED light is synchronized with output It shows how much power the regulator is sending out as a 12VDC control s...

Page 2: ...e at set point When boiling control mode is selected the controller functions as a power regulator It allows the user to manually adjusting the power to control the strength of the boil Figure 4 shows...

Page 3: ...ps figure 5 MASH for mashing control BOIL for boiling control and SYST for system configuration The same type of parameter may have slightly different names when used in different mode For example the...

Page 4: ...ted with their appearance The temperature reading has two or three digits For example 212 degrees will be displayed as 212 The timer display has four digits with flashing colon in the middle For examp...

Page 5: ...he boiling Since the heater power and liquid volume varies between each application we suggest the bAST to be set at least 5 degree Fahrenheit below the boiling point for the first time use As you get...

Page 6: ...to a very long time so that it will not end before operator decide to end the mash The counting direction should be up Use the reset button rSt to reset the timer at any time tF on tSP 50 tdIr up EO o...

Page 7: ...er Figure 5 Original AC sine wave is overlaid with SSVR output wave form The blue colored area shows the power output that has been blocked 2 Time proportional firing A fixed cycle time needs to be de...

Page 8: ...nal drop to zero the AC power is blocked 3 Burst firing This method is similar to time proportional firing section 2 But in contrast to the time proportional mode where the SSR is fired once for each...

Page 9: ...SPR detects the frequency and phase of the AC power line so that the pulse width and firing time is synchronized with AC cycle Auber Instruments 5755 North Point Parkway Suite 99 Alpharetta GA 30022 w...