Thank you for choosing an Aube product.
The TH131 and TH133 non programmable thermostats
are equipped with a microprocessor and proportional
integral adaptive (PIA) temperature control technology.
They can be installed on a 230 V power base (European
model) or a 24 V low voltage base and combined with an
electromechanical or TRIAC relay.
The TH131 can use all six pilot wire commands when
installed on a 230 V power base (see section 4).
7HPSHUDWXUH &RQWURO $ DQG $) RQO\
Position the switch according to your application:
+HDWLQJ &\FOHV
Ͽ
230 V LINE VOLTAGE BASE
ALWAYS 15 minutes
Ͽ
24 V LOW VOLTAGE BASE
• 15 MIN
Use with a TRIAC or
electromechanical relay.
Recommended for mechanical
actuated system (water heating
using a solenoid valve, etc.) or a
fan-forced heater.
• 15 SEC
Use only for installations with a solid state relay
(SSR). Recommended for electric heating
(baseboards, convectors, etc.).
212)) 6ZLWFK 7+ RQO\
The thermostat also features an On/Off switch making it
possible to turn off the thermostat when it is not required
(e.g. summer).
Use this feature to establish a temperature range by
setting minimum and maximum setpoints. Depending on
the model, you can establish the temperature range for:
Ͽ
the ambient air (A)
Ͽ
the floor (AF and F)
Use a flat tip screwdriver to
rotate the potentiometers
until the notch points to the
desired temperature.
([DPSOH
When the temperature is
set outside the temperature
range, it will revert to the
nearest setpoint.
Example: MIN is 59°F and MAX is 77°F.
Ͽ
Using the front dial, you set the temperature at 50°F,
the TH131 will revert to the minimum set value 59°F.
Ͽ
Using the front dial, you set the temperature at 86°F,
the TH131 will revert to the maximum set value 77°F.
TH1 31 & TH1 33 A/AF/F
User Guide
Control Module
TH133
Heating command
Indicator
Temperature
selection dial
ON/OFF switch
TH131
Pilot wire
indicator
(European
model only
230 V
Model
Switch
Temperature Control
A
UP (A/AF)
AMBIENT
(no floor sensor)
AF
UP (A/AF)
AMBIENT WITH FLOOR LIMIT
(requires a floor sensor)
F
DOWN (F)
FLOOR
(requires a floor sensor)
(ambient sensor is deactivated)
Configure the Switches
Min/Max Temperature (TH1 31 only)
Align the bracket tabs on the control module with the
holes located on the power base and secure using the
screw.
NOTE:
Keep the thermostat's air vents clean and free
from obstructions.
NOTE:
The screw cannot be removed completely.
EUROPEAN MODEL ONLY (230 V BASE)
The TH131 accepts the six pilot wire commands:
Models
: TH131 and TH133 A / AF / F
Setting Range
: 45°F, 59°F to 95°F (7°C, 15°C to 35°C)
MIN: above-freezing temperature 45°F (7°C)
MAX: maximum temperature 95°F (35°C)
Potentiometers
:
MIN: 41°F to 77°F (5°C to 25°C)
MAX: 59°F to 95°F (15°C to 35°C)
Storage
: -4°F to 120°F (-20°C to 50°C)
Software
: Class A
Controller
: Electronic
Temperature Control
: Proportional integral adaptive,
15-minute or 15-second heating cycles
Accuracy
: ± 0.36°F (0.2°C)
Size (H/W/D)
:
TH131: 3.1 x 3.1 x 0.64 in (78.9 x 78.9 x 16.3 mm)
TH133: 3.1 x 3.1 x 0.71 in (78.9 x 78.9 x 18 mm)
AUBE TECHNOLOGIES INC. TWO (2) YEAR LIMITED WARRANTY
This product is guaranteed against workmanship defects for a two-year
period following the initial date of purchase. During this period, AUBE
Technologies Inc. will repair or replace, at our option and without charge,
any defective product which has been used under normal conditions.
The warranty does not cover delivery costs and does not apply to products
poorly installed or randomly damaged following installation. This warranty
cancels and replaces any other manufacturer's express or implied
warranty as well as any other company commitment.
AUBE Technologies Inc. cannot be held liable for related or random
damages following the installation of this product. The defective product as
well as the purchase invoice must be returned to the place of purchase or
mailed, prepaid and insured, to the nearest address.
If you have any questions concerning the TH131 or TH133 thermostat, call
our technical support team at:
Install the Control Module
Control Module
Power Base
MODE
1
1.
1) Comfort 2) Reduced setpoint 3) Above freezing (min)
4) Stop heating 5) 1°C setback 6) 2°C setback
SIGNAL
COMMAND
1
No signal
Heating as per
defined setpoint
2
Current setpoint
minus 3,5°C
3
Setpoint at 7°C
4
Stop heating
5
Current setpoint
minus 1°C
6
Current setpoint
minus 2°C
Pilot Wire Commands
Technical Specifications