Aube Technologies TH114 User Manual Download Page 1

TH1 1 4

User s Guide

Non-programmable Thermostat

TH114

      400-114-000-B                    21/2/05                    1/2

Aube’s TH114 Series non-programmable thermostats can be used
to control ambient or floor temperature. The following models are
available:

Each thermostat consists of a control module which must be
mounted on a PB112 Series power base. For the selection and
installation of the power base, refer to its installation instructions.

The DIP switches are located at
the back of the control module.

2.1 Temperature Display (S1 )

To switch between °C and °F.

2.2 Model (S2)

Note

: Available on certain models only

n

Refer to the installation instructions of the 
power base.

o

Insert the tabs at the top of the control 
module in the slots at the top of the 
power base.

p

Secure the control module using the cap-
tive screw underneath the base

.

Note

: Do not obstruct the thermostat's vents.

As soon as the thermostat is powered, it undergoes a
series of tests before displaying the actual tempera-
ture.

The measured temperature is below 0°C (32°F). Heat-
ing is turned On.

The measured temperature is above 50°C (122°F) (A
or AF model) or 60°C (140°F) (F model).

The floor sensor is defective or not properly connected
(F model only), or the thermostat is defective.

Note

: This procedure must be performed if the thermostat is

mounted on a GFCI-equipped power base.

Test the GFCI immediately after installing
the control module, and once a month there-
after.

n

Raise the temperature 

 until the heat-

ing power indicator 

 appears.

o

Press the Test button.

p

If the test is successful, you will hear a 
click caused by the GFCI relay tripping. 
The heating power indicator will disap-
pear, GFI will appear and the Fault light 
will illuminate. Reset the thermostat by 
switching it to Standby and back to On.

q

If the test has failed, cut power to the heating system from the 
main electrical panel and call customer service.

Note

: If the Fault light is On during normal operation, cut power to

heating system at the main electrical panel and have an electrician
verify the installation.

1 . Description

A model:

Ͽ

controls and displays the ambient temperature

F model:

Ͽ

controls and displays the floor temperature

Ͽ

uses an external temperature sensor

AF model:

Ͽ

controls and displays the ambient temperature

Ͽ

maintains the floor temperature within desired
limits

Ͽ

uses an external temperature sensor

2. DIP Switch Configuration

F

:

To select the F model

AF

: To select the A or AF model

1 to 24%

25 to 49%

50 to 74%

75 to 99%

100%

GFCI test button * /
Backlight button *

Temperature 
adjustment button

On/Standby button

Power output

Actual or setpoint 
temperature

Arrow appears 
when the setpoint 
is displayed

GFCI fault indicator *

GFCI fault light *

* available on certain models only

3. Installation

4. Power-up

5. Error Messages

6. GFCI Test