MODEL TH111GFCI-NP 120 VAC

SUMMARY

OPTIONS SELECTION

At  the  back  of  the  thermostat,  there  is  one  selection  switches  to  set  at

your preferences.
Temperature in °C or °F.

TO SET TEMPERATURE

Press  on  or  once  to  see  setpoint  temperature  appear  on  display.  Every

subsequent press will change the setpoint temperature by one degree.

TO RECORD THE      (COMFORT) SETPOINT TEMPERATURE

Select  chosen  setpoint  temperature  by  using 

or 

button.  Press  on

button (2 to 3 seconds) until icon appears on display.

TO RECORD THE     (ECONOMIC) SETPOINT TEMPERATURE

Select  chosen  setpoint  temperature  by  using      or      button.  Press  on

button (2 to 3 seconds) until icon appears on display .

TO RECORD THE       (VACATION) SETPOINT TEMPERATURE

To  program  the  Vacation  temperature,  select  the  desired  degree  using  the

buttons and press on the       and     buttons simultaneously until the  

icon is displayed (app. 3 seconds).

CHECKING GROUND FAULT CIRCUIT INTERRUPTER (GFCI)

Adjust  the  setpoint  temperature  until  heating  indicator  (flames)  appears  on

display. Press TEST button. The test is conclusive if the warning light (GFCI) on

thermostat  is  ON  and  power  to  the  load  is  cut-off  (flames  remain  on  display

though). If these events do not occur, check the installation. Press on RESET but-

ton to reset the GFCI.

INSTALLATION

Parts included:

One (1)

TH111GFCI-NP (120 VAC) thermostat

Two (2)

6-32 screws

Four (4)

Solderless connectors (for copper wire)

One (1)

Temperature sensor with a 15 foot extension

TURN  OFF  POWER  TO  THE  HEATING  SYSTEM  AT  THE  MAIN  POWER

PANEL  TO  AVOID  ELECTRICAL  SHOCK.  KEEP  AIR  VENTS  OF  THE

THERMOSTAT CLEAN AND OBSTRUCTION FREE.

This thermostat should be installed by an electrician or experienced technician.

The thermostat must be used with a circuit breaker or fuse.

This  thermostat  was  designed  to  control  floor  electric  heating  systems.  The

resistive  load  must  not  exceed  2000  watts  @  120  VAC  (16.7  A).  The

thermostat  is  equipped  with  a  ground  fault  circuit  interrupter  (GFCI)  and

therefore  the  isolation  of  the  line  and  load  is  required  for  operation.  The

polarity of line connection must be respected. During a ground fault, only the

current  in  the  black  wire  of  the  load  will  be  cut-off  from  the  120  V  line.

Connect thermostat as shown on diagram.

1) CONNECTING WIRES AND MOUNTING THERMOSTAT

Connect the rear thermostat wires to the power supply and to the load using 

solderless connectors for copper wires. See schematic diagram.

Push  the  excess  wire  back  into  the  electrical  box  to  prevent  interference

withthe  thermostat.  Secure  the  thermostat  using  two  (2)  6-32  screws

1  1/4  inches  long.  Once  the  thermostat  is  properly  installed,  return  power

to heating system. 

2) CONNECTING TEMPERATURE SENSOR WIRE

Connect the sensor wire to the two lower screws of the terminal block at the

back of the thermostat (no polarity need to be respected). The wire must pass

outside the electrical box and follow the wall down to the floor. The sensing

probe  should  be  placed  in  a  representative  heat  area  for  maximum  system

perfomance. The sensing probe should be centered between the wires in the

mat. The probe wire cannot cross any heater wires and the temperature sensor

must not be directly or adjacent to a heating wire.

VAC

120

60 HZ

720-111715-B   1/2

CHOOSING  THE  TEMPERATURE  SCALE  IN  °C  (CELSIUS)  OR  °F

(FAHRENHEIT) TO APPEAR ON DISPLAY.

Set  the  temperature  switch  at  the  back  of  the  thermostat  to  °C  or  °F  at  your

preferences.