Aube Technologies TH109PLUS Owner'S Manual Download Page 1

TH109PLUS

Non-programmable Thermostat

Owner’s 
Guide 

400-109-005-A   2009-11-30

400-109-005-A (Calypso) ENG.fm  Page -1  Monday, November 30, 2009  2:36 PM

Summary of Contents for TH109PLUS

Page 1: ...TH109PLUS Non programmable Thermostat Owner s Guide 400 109 005 A 2009 11 30 400 109 005 A Calypso ENG fm Page 1 Monday November 30 2009 2 36 PM...

Page 2: ...idelines 3 Mounting the thermostat 4 Wiring 5 Configuration switches 6 Operation Temperature display and setting 7 Setup menu 8 Appendices In case of difficulty 9 Specifications 10 3 year limited warr...

Page 3: ...esistive load under 2 A a resistive load over 12 5 A a system driven by a contactor or a relay inductive load a central heating system SUPPLIED PARTS One 1 thermostat Two 2 6 32 mounting screws Two 2...

Page 4: ...g intensity indicator the image disappears when heating is off Appears when the setpoint is displayed Appears when the thermostat is configured for a fan forced heater see page 6 The settings are lock...

Page 5: ...stat on a wall section that conceals air ducts chim ney pipes or stove pipes Install the thermostat about 1 5 m 5 feet high on an inside wall facing the heater Install the thermostat onto an electrica...

Page 6: ...ounting holes of the wallplate q Set the configuration switches see page 6 r Reinstall the faceplate onto the wallplate and tighten the screw NOTE If there is a protective film or sticker on the therm...

Page 7: ...09PLUS 5 Connect the thermostat wires to the heating system load and to the power supply Wiring 2 wire Installation 4 wire Installation 400 109 005 A Calypso ENG fm Page 5 Monday November 30 2009 2 36...

Page 8: ...ge 2 when the settings are locked 2 Place at Fan Yes if you have a fan forced heater to prevent premature burn out of the motor Leave at No for better temperature regulation if you do not have a fan f...

Page 9: ...setpoint temperature will remain on the screen for 5 seconds To change the setpoint temperature press the Up or Down button repeatedly until the desired temperature is displayed The screen is backlit...

Page 10: ...hanges and exit the menu NOTE If you do not press any button for 15 seconds the thermostat will automati cally save any changes you have made and will then return to its normal display Setup menu Para...

Page 11: ...ve a heat source such as a light dimmer Display disappears and reappears after a few minutes The thermal circuit breaker on the heater has temporarily opened This can happen if the heater is obstructe...

Page 12: ...32 F to 122 F Setpoint range 5 0 C to 30 0 C 41 F to 86 F Resolution 0 5 C 1 F Operating temperature 0 C to 50 0 C 32 F to 122 F Storage temperature 20 0 C to 50 0 C 4 F to 122 F Permanent memory You...

Page 13: ...well s sole responsibility shall be to repair or replace the product within the terms stated above HONEYWELL SHALL NOT BE LIABLE FOR ANY LOSS OR DAMAGE OF ANY KIND INCLUDING ANY INCIDENTAL OR CONSEQUE...

Page 14: ...or use contact us at 705 Montrichard Avenue Saint Jean sur Richelieu Quebec J2X 5K8 Canada 1 800 831 2823 Email aube service honeywell com For more information on our products go to www aubetech com C...

Reviews: