CRAFT LINE INTERFACE (CLI)
5-24
TranScend Chassis – Operation Manual
Example #1: In this example, the module in slot 1 reports the alarm status of laser RF as “MajorLoLo” (e.g. Major
alarm with reading below the low low threshold).
Transcend [slot-1] >LaserRfAlarm
MajorLoLo
ModuleTempAlarm:
Displays the alarm status of module temperature.
Example #1: In this example, the module in slot 1 reports the alarm status of module temperature as Normal.
Transcend [slot-1] >ModuleTempAlarm
Normal
5.1.2.14 Opto-Stacker
The commands in this section are Opto-stacker specific.
ModuleTemp:
Displays the module temperature reading in Centigrade.
Example #1: In this example, the module in slot 1 reports its module temperature reading as 21.4 Centigrade.
Transcend [slot-1] >ModuleTemp
+21.4 deg C
LaserTemp:
Displays the laser temperature reading in Centigrade.
Example #1: In this example, the module in slot 1 reports its laser temperature #1 reading.
Transcend [slot-1] >LaserTemp 1
+23.0 (deg C)
OPoutPower:
Displays the optical output power reading in dBm.
Example #1: In this example, the module in slot 1 reports its optical output power #1 reading.
Transcend [slot-1] >OPoutPower 1
-99.0
dBm
Mode:
Displays the gain control mode setting.
Example #1: In this example, the module in slot 1 reports its channel #1 gain control mode.
Transcend [slot-1] >Mode 1
MGC
OpticalPowerdBm:
Displays the optical input power reading in dBm.
Example #1: In this example, the module in slot 1 reports its optical input power #1 reading.
Transcend [slot-1] >OpticalPowerdBm 1
-99.0
dBm
CHAPTER 5: