TranScend Chassis – Operation Manual
OpticalPowerAlarm:
Displays the alarm status of optical power.
Example #1: In this example, the module in slot 1 reports the alarm status of optical power as “MajorLoLo” (e.g.
Major alarm with power reading below the low low threshold).
Transcend [slot-1] >OpticalPowerAlarm
MajorLoLo
LockAlarm:
Displays the alarm status of synthesizer lock. It’s an alarm condition when synthesizer loses its lock.
Example #1: In this example, the module in slot 1 reports the alarm status of synthesizer lock as “Major” on
channel 1.
Transcend [slot-1] >LockAlarm 1
Major
ModuleTempAlarm:
Displays the alarm status of module temperature.
Example #1: In this example, the module in slot 1 reports the alarm status of module temperature as Normal.
Transcend [slot-1] >ModuleTempalarm
Normal
5.1.2.6 Stacker
The commands in this section are Stacker specific.
ModuleTemp:
Displays the module temperature reading in Centigrade.
Example #1: In this example, the module in slot 1 reports its module temperature reading as 21.4 Centigrade.
Transcend [slot-1] >ModuleTemp
+21.4 (deg C)
LaserTemp:
Displays the laser temperature reading in Centigrade.
Example #1: In this example, the module in slot 1 reports its laser temperature reading on channel 1.
Transcend [slot-1] >LaserTemp 1
+23.0 (deg C)
OpticalPowerDbm:
Displays the optical receiver power in dBm.
Example #1: In this example, the module in slot 1 reports its optical receiver power reading as -8.0 dBm.
Transcend [slot-1] >OpticalPowerdBm
-8.0
(dBm)
LaserTempAlarm:
Displays the alarm status of laser temperature.
Example #1: In this example, the module in slot 1 reports the alarm status of laser temperature as “MajorLoLo”
(e.g. Major alarm with power reading below the low low threshold).