CRAFT LINE INTERFACE (CLI)
5-8
TranScend Chassis – Operation Manual
Transcend [slot-1] >OPinPowerAlarm 1
MajorLoLo
OPoutPowerAlarm:
Displays the alarm status of optical output power.
Example #1: In this example, the module in slot 1 reports the alarm status of optical output power as “MajorLoLo”
(e.g. Major alarm with power reading below the low low threshold).
Transcend [slot-1] >OPoutPowerAlarm 1
MajorLoLo
ModuleTempAlarm:
Displays the alarm status of module temperature.
Example #1: In this example, the module in slot 1 reports the alarm status of module temperature as Normal.
Transcend [slot-1] >ModuleTempAlarm
Normal
ShutoffAlarm:
Displays the status of pump shut off state. It’s an alarm state when pump is shut off.
Example #1: In this example, the pump of the module in slot 1 is shut off.
Transcend [slot-1] >ShutoffAlarm
Major (Enable)
5.1.2.4 Quad Return Receiver
The commands in this section are Quad Return Receiver specific.
ModuleTemp:
Displays the module temperature reading in Centigrade.
Example #1: In this example, the module in slot 1 reports its module temperature reading as 21.4 Centigrade.
Transcend [slot-1] >moduletemp
+21.4 (deg C)
OpticalPowerDbm:
Displays the optical receiver power in dBm.
Example #1: In this example, the module in slot 1 reports its optical receiver power reading as -8.0 dBm on channel 1.
Transcend [slot-1] >opticalPowerdbm 1
-8.0
(dBm)
Attenuation:
Displays the attenuation setting in dB.
Example #1: In this example, the module in slot 1 reports its attenuation setting as 0 dB on channel 1.
Transcend [slot-1] >attenuation 1
0
(dB)
OpticalPowerAlarm:
Displays the alarm status of optical receiver power.
CHAPTER 5: