ATX Q-Series Power BAQ-UP Installation & Operation Manual Download Page 9

           Q-Series

®

 Power – BAQ-UP™ (QRED) Redundancy Switch with Backup Amplifier – Installation & Operation Manual  

3-1

CHAPTER 3: SET-UP PROCEDURE

SET-UP PROCEDURE

3. 

Set-up Procedure

1.  Remove the cover.
2.  Connect input signal to the “Input” of the RF switch compartment.

3.  Connect the “Output to Secondary Amp” of the RF switch compartment to the “Input” of the amplifier compartment.  
4.  Connect the “Output” of the amplifier compartment to the “Input from Secondary Amp” of the RF switch compartment.
5.  Connect the “Output to Primary Amp” of the RF switch compartment to the “Input” of an external amplifier.
6.  Connect the “Output” of the external amplifier to the “Input from Primary Amp” of the RF switch compartment.

7.  Connect signal strength meter to the “Output” of the RF switch compartment.

8.  Adjust the external amplifier to get the desired level.

9.  Connect 24 VDC or 24 VAC to the appropriate input of the power supply compartment.
10.  Push the “Set Ref. Levels” switch.

11.  Connect the “+” and “-” contact of the remote switch with a jumper to force the microcontroller switch to the secondary 

amplifier.

12.  Adjust the gain and slope control in the amplifier compartment to get desired signal level.
13.  Remove the jumper from the remote switch.

14.   Remove the signal strength meter from the “Output” of the RF switch compartment.
15.  Connect the “Output” of the RF switch compartment to the desired output cable.

16.  Use a voltmeter to measure the DC voltage on the “Secondary Amp DC Level” test point. Adjust the variable attenuator 

on the secondary amp level detector to get the voltage to a nominal 2.5V if possible. (For lower RF levels, the detected 

DC voltage may not reach 2.5 VDC. This is normal).

17.  Use the voltmeter to measure the DC voltage on the “Primary Amp DC Level” test point. Adjust the variable attenuator 

on the primary amp level detector to get the voltage close to the voltage on the “Secondary Amp DC Level” test point.

18.  Put the cover back on.
19.  Press “Controller Reset”.
20.  Press “Set Ref Levels”.
SET UP PROCEDURE IS COMPLETE

Summary of Contents for Q-Series Power BAQ-UP

Page 1: ...BAQ UP QRED Redundancy Switch with Backup Amplifier Q SERIES Power Installation Operation Manual ...

Page 2: ... by one or more U S or foreign patents Other non ATX product and company names in this manual are the property of their respective companies Although every effort has been taken to ensure the accuracy of this document it may be necessary without notice to make amendments or correct omissions Specifications subject to change without notice ...

Page 3: ...nstallation Operation Manual i TABLE OF CONTENTS Page 1 DESCRIPTION OF INTERFACES 1 1 2 DESCRIPTION OF OPERATION 2 1 2 1 Functional Schematic 2 2 3 SET UP PROCEDURE 3 1 4 SPECIFICATIONS 4 1 5 SERVICE SUPPORT 5 1 5 1 Contact ATX Networks 5 1 5 2 Warranty Information 5 1 ...

Page 4: ...ii Q Series Power BAQ UP QRED Redundancy Switch with Backup Amplifier Installation Operation Manual This page left intentionally blank ...

Page 5: ...over removed Input Test Point Output Test Point Gain Control Slope Control Input Pad used to optimize the input to the amplifier Description This is referred to as the secondary amplifier because your existing amplifier is referred to as the primary amplifier This internal amplifier has a low noise front end and is comparable in signal quality to any primary amplifier RF Switch Compartment Left si...

Page 6: ...ED 5V power on Yellow LED warning On using reference levels stored in EEPROM Flashing 1 sec Needs to set reference levels Flashing 3 sec Switched to the secondary amplifier by the remote control switch Red LED alarm On Primary amp failure Flashing 1 sec Secondary amp failure Flashing 3 sec Input signal low primary amp and secondary amp failure RF Detectors Primary Amp RF Level Detector DC level pr...

Page 7: ...ickly and set the alarms The system needs to be reset at this point to get back to normal operation after correcting the input levels If the system is running on the primary amp and the secondary amp level is down 3 dB or more the system considers the secondary amp failed and will set Alarm 2 and set the red LED flashing slowly The system should be reset at this point to get back to normal operati...

Page 8: ...ed to switch to the secondary amplifier when the cumulative RF output of the primary amplifier falls below a programmed level usually a 3 dB drop This output is measured within a frequency range from 120 220 MHz The microprocessor controlled switch can be programmed to switch within the end users specifications for timing and RF levels Once a switch is made to the secondary amplifier the signal pa...

Page 9: ...mpartment 10 Push the Set Ref Levels switch 11 Connect the and contact of the remote switch with a jumper to force the microcontroller switch to the secondary amplifier 12 Adjust the gain and slope control in the amplifier compartment to get desired signal level 13 Remove the jumper from the remote switch 14 Remove the signal strength meter from the Output of the RF switch compartment 15 Connect t...

Page 10: ...3 2 Q Series Power BAQ UP QRED Redundancy Switch with Backup Amplifier Installation Operation Manual CHAPTER 3 SET UP PROCEDURE This page left intentionally blank ...

Page 11: ...Q Series Power BAQ UP QRED Redundancy Switch with Backup Amplifier Installation Operation Manual 4 1 CHAPTER 4 SPECIFICATIONS SPECIFICATIONS 4 Specifications ...

Page 12: ...4 2 Q Series Power BAQ UP QRED Redundancy Switch with Backup Amplifier Installation Operation Manual CHAPTER 4 SPECIFICATIONS This page left intentionally blank ...

Page 13: ... Free 800 565 7488 USA Canada only Press 3 for Technical Support Then press 1 for Digital Video Products DVIS DigiVu UCrypt etc OR press 2 for All Other Products Email digitalvideosupport atxnetworks com for Digital Video Products Email jleskovar atxnetworks com for All Other Products CUSTOMER SERVICE ATX Networks 1 501 Clements Road West Ajax ON L1S 7H4 Canada Tel 905 428 6068 Toll Free 800 565 7...

Page 14: ...nted in Canada Rev 07 15 ANW0849 1 501 Clements Road West Ajax ON L1S 7H4 Canada Tel 1 905 428 6068 Toll Free 1 800 565 7488 Fax 1 905 427 1964 Toll Free Fax 1 866 427 1964 www atxnetworks com support atxnetworks com ...

Reviews: