background image

SAFETY ALERT SYMBOLS

Safety Symbols alerting you to potential personal safety hazards. Obey all safety
messages following these symbols.

WARNING

CAUTION

avoid possible 

avoid possible

injury or death

injury and/or property damage

FOR YOUR SAFETY READ ALL INSTRUCTIONS

BEFORE INSTALLATION AND OPERATION

INSTALLATION MUST COMPLY WITH ALL APPLICABLE STANDARDS AND CODES.

Installer:

Provide these instructions to the consumer.

Consumer:

Keep documents for future reference.

The Converter/Charger is designed to convert 120 VAC to 
12 VDC. This allows operation of 12 VDC devices while being
connected to shore power; using power from a generator; or
using power from on board storage batteries. It also provides
exceptionally clean low voltage power for charging on board
batteries. This Converter/Charger is a ‘switch mode’ type
supply. Its high frequency electronic design is maintenance
free with superior performance.

The APC Series offers a wide range of power - 32,45, 55 and
75 amp models - in a compact design weighing just six
pounds. Atwood technology maintains safe, cool, reliable
converter/charging operation, ensuring the performance of
electrical systems with sophisticated controls. The
thermostatically controlled cooling fan also reduces noise and
increases warm weather performance. The APC’s circuitry
includes over-temperature and over-current protection,
safeguarding against power supply damage. External fuses
provide “reversed battery” protection, preventing damage from
cross-wiring.

APC filtered power provides smooth, optimum DC appliance
operation and the full output rating is available for battery
charging.

COMMON FEATURES

• Regulated output voltage ensures against erratic charging and

damage to amenities.

• Over current protection prevents battery damage caused by over-

charging.

• Short circuit protection prevents damage to power supply.

• Reverse battery hook-up protection prevents power supply damage

due to cross-wiring.

• Fan cooled prevents unit from over-heating.

• 100% burn-in tested ensures stringent quality assurance.

• 2-year limited warranty.

• ETL listed to UL 458.

INSTALLATION

1. 

DISCONNECT POWER.

Disconnect the RV battery POS (+) wire

at the battery before connecting the Converter/Charger.

WARNING

PERSONAL INJURY/PRODUCT DAMAGE

• 

Never store electrical devices in a compartment where
flammable liquids are stored. 

• 

Do not mount the unit in a compartment designed for the
storage of batteries or flammable liquids (such as gasoline). 

2. 

LOCATION.

Mounting location may be on any interior (out of

direct weather) surface. Location chosen must be
accessible after installation. When mounted inside a
cabinet, the cabinet must be vented and large enough to
allow dissipation of heated air. Make sure that there is a
minimum of 1” (one inch) free air space from sides and back
of the unit so that cooling air can move through the unit
properly. 

AVOID foreign contaminants such as dirt, metal particles or
moisture.

3. 

MOUNTING.

Flanges with holes are provided for ease of

mounting using standard fasteners.  Surface must support
the converter’s weight (6 lbs) during vehicle operation.

ENGLISH

•Installation •Operation •Maintenance

Effective 2/04/08

CONVERTER/CHARGER

APC MODELS: 32, 45, 55 & 75 AMP 

LITERATURE NUMBER

MPD 39065

9

1

SPECIFICATIONS FOR CONVERTERS

PART

EXTERNAL

INPUT

OUTPUT

INPUT

OUTPUT

INPUT

NO

.

MODEL

LBS

.

AMPS

DIM

IN INCHES

VOLTAGE

VOLTAGE

CURRENT

CURRENT

FREQ

.

AC

DC

AMPS

AMPS

HZ

35411

APC32

6

32

10.36 x 7.75 x 3.5

105-130

13.6

7

32

58 to 62

35412

APC45

6

45

10.36 x 7.75 x 3.5

105-130

13.6

10

45

58 to 62

35413

APC55

6

55

10.36 x 7.75 x 3.5

110-130

13.6

13

55

58 to 62

35414

APC75

6

75

10.36 x 7.75 x 3.5

110-130

13.6

15

75

58 to 62

Reviews: