DPX16: Instructions for Basic Operation and Installation
Page 17
Alarm Control Options
Selecting:
1.
Enters the “Set Alarm Hold Times” menu.
2.
Enters the “Set Alarm Activation Type” menu.
3.
Toggles the External Control Input between
picture “Freeze” (factory default) and alarm
“Master Enable”.
4.
Toggles the alarm Master Enable Input Type
between “Logic Low” (factory default) and
“Logic High”.
When the External Control Input is selected to be
picture “Freeze”, a single pulse on the input will freeze
the current picture on the main display. Another single
pulse will return the display to its normal updating mode. When the alarm “Master Enable” mode is
selected, the entire DPX16 alarm system will be enabled or disabled by this input according to the
logic level specified by the “Master Enable Input Type” setting. This input can be used to control the
DPX16 alarm system from a burglar alarm system, or other
external control system.
Alarm Dwell Adjustment
Selecting:
1.
Allows changing the alarm ACTIVATION HOLD
time.
2.
Allows setting of a MAXIMUM time for an alarm to
be displayed.
3.
Allows changing the monitor alarm display
SEQUENCE DWELL time.
Some alarming devices (such as some motion detectors)
generate very brief alarms lasting only a fraction of a
second. The “Hold Detected Alarms for” time is the amount
of time that the alarm event will be held so that the alarm
camera image can be kept on the display screen and
mutiplexed at a high frame rate to the VCR.
The maximum time for holding an alarm display set in the “Disable Detected Alarms after” option will
determine how long a continuous alarm camera will be displayed. This can be adjusted so that a
continuous alarm will not consume all of the VCR’s record time. A value of zero (factory default) will
result in no time limit for an alarm display.
The “Hold Alarmed Images for” time determines the image display hold time during multi-camera
alarms. When multiple alarms occur simultaneously, the monitor display will sequence between all
cameras with alarms using this dwell time. Every alarming camera will be multiplexed to the VCR at a
high priority “alarm” frame rate.
Both delay times are adjustable from 1 to 255 seconds though the default is 1 second for the
activation hold and 3 seconds for the sequence dwell time. Camera buttons are used to enter digits 1
through 9 and the PIP button is used to enter 0. The DISPLAY button stops the editing of a delay
value.
Set Alarm Hold Times
1: Hold Detected Alarms
for: 1 Sec.
2: Disable Detected Alarms
after: 0 Sec.
3: Hold Alarmed Images
for: 3 Sec.
Camera: Select
DISPLAY: Accept and Return
Alarm Control Options
1: Set Alarm Hold Times . . .
2: Set Alarm Activation Type . . .
3: External Control Input: Freeze
4: Master Enable Input Type: Logic Low
Camera: Select
DISPLAY: Accept and Return