40
APPENDIX B -
REMOTE CONTROL OPERATION
RS-232 Remote Control Interface
The multiplexer has a built-in RS-232 serial interface which supports remote control operation
through simple ASCII commands. The commands provide access to the front panel button
operations just like the IR remote control.
The multiplexer serial interface is fixed at 9600 baud, 8-bit, 1 stop bit, and no parity. The
command format is:
command - return
The command is 2 characters or 2 characters plus parameter, and must be followed by a
“carriage return”.
The multiplexer will respond with:
> if the command was recognized, or
? if the command was not recognized or is invalid
Button Commands
BD
DISPLAY button
BR
REC button
BP
PIP button
B2
2nd button
BS SEQUENCE
button
BA ACCEPT
button
BF FREEZE
button
BC CANCEL
button
BQ ROTATE
button
MU Move
UP
BZ ZOOM
button
ML Move
LEFT
BV PLAYBACK
button
MR Move
RIGHT
BO MACRO
button
MD Move
DOWN
BM
MONITOR button
UNIT n
N = 1 ~ 255 unit number
BL ALARM
button
PREV
Preview
BC n
N = 1 ~ 16 Camera number
Immediate Commands
DM m, c, c, ---, q
Set display mode
m = display mode, c = camera mode, q = quadrant
m : 0 = full, 1 = 2x2, 2 = 3x3, 3 = 4x4, 4 = PIP,
5 = Dual PIP, 6 = Split, 7 = Squish, 8 = Center Insert
9 = Split Quad,
q : 0 = lower right, 1 = lower left
TIME hh:mm:ss
Set time
DATE dd/mm/yy
Set date
Ec n
Echo characters. n : 0 = echo off, 1= echo on
EXIT
Main exit menu
ENTER Enter
menu