Application: 

Add an IP camera or other network device to the current network group, the new IP address must not be 

occupied, otherwise it will cause IP conflicts and stop the equipment normal working. Link monitor can 

check if the new setting IP address is occupied. 

3.3.18

  Rapid IP Discovery

 

Connect the cable to tester’s LAN port. Press                to enter Rapid IP Discovery app. 

Click “Start” to search all IP address of connected equipment in whole network segment.   

Click “Stop” to stop work. 

 

                         

 

 

 

 

 

 

 

 

 

3.3.19  PoE power / DC12V 2A and DC 5V 2A USB power output 

When the tester is turned on, the DC 12V and DC 5V power output functions are automatically turned 

on. If the IP tester is turned off, the DC 5V USB can still be used to power an external USB device.   

 

To use the PoE Power Output function, click on the icon            and change the switch “ON” or “OFF”.   

The IP camera needs to be connected to the LAN port before you turn PoE Power on. If the IP camera   

Supports PoE, the PoE power is delivered via pins 1, 2, 3, and 6 on the LAN port. The IP tester will   

display “48V ON” at the top of the screen when the POE power is still on.   

 

Summary of Contents for 4KTESTMON

Page 1: ...IP camera tester User Manual V01 00...

Page 2: ...ead the Safety Information carefully in the manual The manual should be kept well in case of reference Keep the S N label for after sale service within warranty period Product without S N label will b...

Page 3: ...g camera connection 9 3 2 3 HD Coaxial camera connection 10 3 2 4 HDMI IN 11 3 3 OSD menu 11 3 3 1 Lite mode Normal mode 11 3 3 2 Drop down Menu 15 3 3 3 Short cut menu 16 3 3 4 Screen capture 17 3 3...

Page 4: ...3 19 PoE power DC12V 2A and DC 5V 2A USB power output 73 3 3 20 Cable Test 75 3 3 21 RJ45 cable TDR test 76 3 3 22 Cable Tracer 79 3 3 23 TDR cable test Optional 80 3 3 24 PoE Voltage test 83 3 3 25...

Page 5: ...ing 109 3 3 42 File explorer 113 3 3 43 Theme 115 3 4 Audio test 118 3 5 HDMI output 118 3 6 PoE power output 118 3 7 DC12V 2A power output 119 4 Specifications 121 4 1 General Specifications 121 4 2...

Page 6: ...able gas Do not disassemble the instrument since no component inside can be repaired by the user If the disassembly is necessary indeed please contact with the technician of our company The instrument...

Page 7: ...SDI EX SDI cameras as well as testing 4K H 264 4K H 265 camera by mainstream The 1920x1200 resolution enables it to display network HD cameras and analog cameras in high resolution The unit supports m...

Page 8: ...7 4V DC 5000mAh 5 BNC cable 6 RS485 cable 7 SC ST connector Only for optical power meter 8 Multi meter test leads one pair of red and black only for the Multi meter models 9 Output Power cable 10 Aud...

Page 9: ...Page 4 2 3 Function interface...

Page 10: ...he value of the parameter Pan the PTZ right 12 Leftward select the parameter whose value will be changed 13 Downward set function or reduce the value of the parameter Tilt the PTZ downward 14 Confirm...

Page 11: ...N 25 Video signal output BNC interface cable tracer interface 26 CVBS input AHD TVI CVI Coaxial interface AHD TVI CVI Optional 27 Optical power meter interface Optional 28 PoE power supply output or L...

Page 12: ...has built in lithium ion polymer rechargeable battery the tester s bottom power should turn to 0 for safety during transportation the factory default is 0 Using the instrument pls switch power button...

Page 13: ...ge the tester Warnings Not allow insert multi meter pen in the current terminal to measure voltage 3 2 Instrument connection 3 2 1 IP camera connection Power an IP camera with an independent power sup...

Page 14: ...ly the PoE switch and the power sourcing equipment are allowed to connect to the tester s PSE port and the PoE power will be supplied to the IP camera by the tester s LAN port On this condition the te...

Page 15: ...ive and negative connection of the cable 3 2 3 HD Coaxial camera connection SDI EX SDI CVI TVI AHD camera are classified as HD coaxial cameras Hereby the following instruction of how to connect SDI ca...

Page 16: ...3 OSD menu Press the key 2 seconds to turn on Press the key again to turn off short press the key to enter sleep mode press it again to test If tester works abnormally and cannot be turned off Press...

Page 17: ...eral seconds can move the icon to other apps In lite mode click the finger icon in the lower right corner to release lock icon move icons and change function icons sequence Normal mode Tap the screen...

Page 18: ...ess icon several seconds go screen management status Change icons sequence and move it to common tools bar You can move the icon to any pages self define the number of icons in any page Make interface...

Page 19: ...name icon will be auto placed in the new named folder Press the folder several seconds to change the folder name you can move the icon out of folder the folder will be auto deleted until move out all...

Page 20: ...icon CVBS to enter you can test IP and analog camera at the same time Video OUT Click Video OUT to enter floating window connecting the BNC cable to tester and appears analog video monitor interface...

Page 21: ...y you can turn on it and switch functions then press to enter app tap other area on the screen to exit the menu Short cut menu setting you can long press any app in the all applications list it will a...

Page 22: ...screen projection Only for android version The meter creates WIFI hotspot connect mobile phone to the tester s WIFI hotspot or the tester and mobile phone connect to the same Wi fi network Tap icon th...

Page 23: ...he VLC player Media Open Network Streaming and input the RTSP address of on the top instrument two dimensional code click play to view the screen real time projection you also can install VLC player i...

Page 24: ...Page 19 3 3 6 Rapid video Press enter function One key to detect all network cameras and auto play the images Auto log in and display camera image Detailed operation refer to ONVIF function...

Page 25: ...P to the same network segment with the scanned camera s IP Local IP Tester s IP address Tester can auto modify the tester s IP to the same network segment with the scanned camera s IP Discovery IP Con...

Page 26: ...irst two digits of camera s IP address it can auto scan the whole network segment IP and auto modify tester s IP address greatly improved engineering efficiency 3 3 8 Rapid ONVIF test Rapid ONVIF can...

Page 27: ...ster can auto login camera and display camera image Click the button Refresh tester will scan the ONVIF camera again Click the newly displayed ONVIF camera on the Device List The tester will show the...

Page 28: ...Page 23 Enter a new password for the camera When comes out activate success prompt click login to display camera image...

Page 29: ...work segments to scan camera s IP Auto Login After open this function tester can auto login camera and display camera image The login password is the same with last time the first time using password...

Page 30: ...tools Snapshot Record Photo Playback PTZ and Settings ONVIF PTZ control Tap the image in the direction you want the PTZ camera to move Tap the left side of the image to move left right to go right up...

Page 31: ...Page 26 IP camera video settings Click Video Set to enter the IP camera s encoder and resolution settings Make the desired changes and click OK to save...

Page 32: ...ging Set to adjust image brightness saturation contrast sharpness and backlight compensation mode Profiles Click profiles can view video streaming current configuration files as well as switch between...

Page 33: ...Page 28 Preview pictures Quickly preview and zoom in or out pictures automatically and manual refresh Identification click Identification to view information of the camera...

Page 34: ...Page 29 Time set Click Time set Select Manual set to set up the time of camera Maintenance For camera software reset or restore to factory settings...

Page 35: ...ge 30 User Set Modify camera user name password etc parameters Network setting Click Network Set to change the IP address Some cameras cannot support change IP address so there is no change after savi...

Page 36: ...e key to zoom out press upward and downward key to move image If it is network video input to the tester as the tester supports resolution up to 1080p the input image will be very clear after it is en...

Page 37: ...rage the tester auto stores the files after snapshot Record When you click bottom the Record icon video starts recording A red recording icon appears on the screen and begins to flash and a timer appe...

Page 38: ...rs Video files can play in the Video player on the main menu PTZ Set preset position Move the camera to preset position enter the preset number on the Bottom right corner to complete position preset C...

Page 39: ...PTZ Speed set Horizontal and Vertical Speed set RTSP Get RTSP address of the current camera Doc Auto create testing reports document of camera click Create document Click Preview to view the report d...

Page 40: ...nter the camera test information click Create Document to complete the report Click Doc menu again you can preview the report document Icons description The description of function icons on the bottom...

Page 41: ...nterface Local IP This is the tester s IP address Click Edit to enter IP setting and change the tester s IP address settings IP camera type Click on the IP Camera type to select the Manufacturer and m...

Page 42: ...nually selecting IP Camera s IP Enter the IP camera s IP address manually or click Search to auto scan for the IP camera s IP address It is better to directly connect the IP camera to the tester so th...

Page 43: ...interface Once you are viewing video on the IPC Test app you will see the Video Menu icon on the top right This button will give you access to Snapshot Record Photo Playback PTZ and Set Please refer...

Page 44: ...de an Input Name pop up box will appear and you can enter a title for the snapshot If the unit is set up to automatically set file names this box will not pop up 2 Video record When you click the Reco...

Page 45: ...hinese character English letter or digit to store in SD card tester will hereby store the files in SD card after recording if select Auto storage tester will auto store the files in SD card after reco...

Page 46: ...mage click and hold on the file until this screen below appears Click to close and return to PTZ controller 4 Recorded video playback Click the Playback icon to view your recorded videos Tap on the vi...

Page 47: ...he file until this screen appears Video files also can play in the main menu Video Player 3 3 11 Video monitor test Analog camera test and PTZ control click icon to enter Display the input video image...

Page 48: ...ct and click icon PTZ to enter PTZ setting A Protocol Use the up and down arrow keys to move the yellow cursor to the protocol set corresponding Protocol and support more than thirty PTZ protocols Suc...

Page 49: ...cial preset number can call the dome camera menu Check and set the protocols address interface and baud all must be consistent with the dome camera then the IPC tester can test After setting the param...

Page 50: ...nual storage When select manual storage user can name and store the files 3 4 x zoom image display and Video out When image input press to enter zoom press it again to quit Using the touch screen to c...

Page 51: ...e manual mode an Input Name pop up box will appear and you can enter a title for the snapshot If the unit is set up to automatically set file names this box will not pop up 5 Video record When you cli...

Page 52: ...ecording 6 Photo Click the icon photo to enter click the selected thumbnail photo to display it on the screen Double tap the image you want to view to make it full screen Double click again the photo...

Page 53: ...mage click and hold on the file until this screen below appears Click to close and return to PTZ controller 7 Recorded video playback Click the Playback icon to view your recorded videos Tap on the vi...

Page 54: ...ter Click the icon to enter the IP camera tester has adopted hardware high speed sampling and processing technology can perform both NTSC and PAL video amplitude signal measurements for PEAK to PEAK S...

Page 55: ...TSC format the SYNC level is 40 5IRE For PAL format the SYNC level is 300 35mV If the level is too low it will cause the image to not frame out properly If the level is too high it will lead to a poor...

Page 56: ...receiver and video cable connect one end to the tester VIDEO OUT port and the other end connected to VIDEO IN port the signal send via VIDEO OUT port and received via VIDEO IN port If the testing is...

Page 57: ...ing the dome camera the tester sends out the color bar by its BNC output to the monitor at the monitoring center If the monitor receive the color bar it means the video transmit channel works normally...

Page 58: ...n The tester supports resolution as follows 1280x720P 25Hz 1280x720P 30Hz 1280x720P 50Hz 1280x720P 60Hz 1920x1080P 25Hz 1920x1080P 30Hz 1920x1080I 50Hz 1920x1080I 60Hz IPC tester s HDMI output port ca...

Page 59: ...amera test and PTZ control click icon to enter When HD CVI signal input the tester will display the image resolution on the top bar Double taps on the screen to make the image displayed full screen Th...

Page 60: ...l PTZ control Click the icon PTZ on the right toolbar to do the corresponding setting Port select coaxial control Enter PTZ address to perform parameters setting Operation instructions please refer to...

Page 61: ...ight upward and downward on the touch screen to control the PTZ rotation direction PTZ cameras will rotate accordingly By two fingers move outward and inward on the touch screen to zoom in and out the...

Page 62: ...to the preset position then Tap it and input preset position number Tap Set position to complete set preset position Call preset position Tap the preset position Tap the preset position area input pre...

Page 63: ...PTZ control parameters setting 2 Coaxial camera menu setting Tap icon UTC select menu setting to enter the dome camera menu Input calling dome camera menu address code after finishing the parameter s...

Page 64: ...Page 59 Press arrow keys to set 3 Snapshot record photo viewer and video play back please refer to 3 3 1 PTZ 1 Video monitor test...

Page 65: ...enu or press the key to close camera menu 4 Save setting Click icon Set on the right toolbar to enter storage setting Support auto storage and manual storage When select manual storage user can name a...

Page 66: ...Double taps on the screen to make the image displayed full screen The tester supports resolution as follows 1280x720P 25FPS 1280x720P30FPS 1280x720P 50FPS 1280x720P 60FPS 1920x1080P 25FPS 1920x1080P 3...

Page 67: ...nput calling dome camera menu address code after finishing the parameter settings you can press the key or click the icon to call the dome camera menu More operation instructions such as PTZ control c...

Page 68: ...y the image resolution on the top bar Double taps on the screen to make the image displayed full screen The tester supports resolution as follows 1280x720P 25FPS 1280x720P 30FPS 1920x1080P 25FPS 1920x...

Page 69: ...o parameters setting is needed More operation instructions please refer to 3 3 6 CVI camera test 3 3 17 Network tool 1 IP address scan Connect the cable to the LAN port click icon to enter Set your IP...

Page 70: ...mote IP address e g IP camera Packet count Packet Size Packet time and Timeout Press Start to start pinging If the IP camera or network device is not configured properly or not plugged in it will say...

Page 71: ...st To use the Network tester you will need two IP testers One is used as a Server and the other as a Client Both devices must be on the same network segment in order to communicate Click the icon to o...

Page 72: ...d testing Click the Start button to send the packets and start testing Network bandwidth testing can also be tested with a computer using compatible network bandwidth testing software Install network...

Page 73: ...r and the Client are at the same network segment but with different IP address Input Server s IP address 192 168 0 39 in the tester and click Start to test network bandwidth Or use tester as a Server...

Page 74: ...erver shows results 4 Port Flashing Connect a network cable to the meter s LAN port click the icon to open the Port Flashing app Click Start The IP tester sends a unique signal to make the connected L...

Page 75: ...LAN port Application The tester will send special signals to make the connected LAN port flicker at special frequency which will enable the installers to easily and quickly find the connected Ethernet...

Page 76: ...P cameras and other networked devices Click the Refresh button to check your Client list 6 Trace route It is used to determine path of the IP packet access target Note Trace route testing results only...

Page 77: ...cts Click Add and enter the desired IP address To test different network segments click the Settings icon on the main menu and go to IP Settings and make the desired changes Once the desired IP addres...

Page 78: ...etwork segment Click Stop to stop work 3 3 19 PoE power DC12V 2A and DC 5V 2A USB power output When the tester is turned on the DC 12V and DC 5V power output functions are automatically turned on If t...

Page 79: ...tection mode Disconnect all the connections of the tester and then connect the tester with power adaptor to resume the tester 4 Before turning on the PoE power output please make sure the IP camera su...

Page 80: ...sequence of wires as well as the serial number of the cable tester kit will be displayed The number of the cable tester is 255 If need several different number other types cable testers should pay the...

Page 81: ...ue to test cable status length and attenuation Status After link up screen display online if not link up or open circuit screen display open circuit if cable pair is short circuit screen display short...

Page 82: ...tion reflectivity impedance skew and other parameters Attenuation reflectivity After link up if reflectivity value is 0 it is the best quality communication Impedance After link up if the impedance va...

Page 83: ...Page 78 Connection diagram Cable sequence diagram A straight through and cross over cable diagram the cable sequence display for reference Click Help check the instruction of all parameters...

Page 84: ...tons on your blue cable identifier to adjust the volume Note Install two AAA batteries in your blue Cable Identifier Note While the cable tracer is receiving the audio signal from the tester it may be...

Page 85: ...t be connected to any equipment otherwise it will damage the tester Connect Alligator clip cable to the TDR port and the cable must connect well before testing otherwise it will influence the accurac...

Page 86: ...ined 1 for calibration 11 groups user defined can be set 1 Select user defined and click Calibration to enter test click user defined 1 can define cable name such as AiPu BNC 5 2 Click Cable Type to s...

Page 87: ...pulse signal for tested cable when cable is open circuit or short circuit reflected pulse is generated the tester receives and deals with the reflected wave measurement results displayed on the screen...

Page 88: ...must be between the PoE switch and the PoE node for this test to work Note The PoE switch must be connected to the PSE IN port The powered device such as IP camera or other PoE node must be connected...

Page 89: ...urrent adaptor input voltage and power Note the current 12V input measured power is the battery charging power and the device working power the measured power will change depending on the different of...

Page 90: ...Measuring AC DC Voltage and current measurement state display Auto range The Multimeter auto adjust the range by input signal or tested components Data hold Hold data Relative measurement Display the...

Page 91: ...lead to the COM jack and the red test lead to the V jack b select U enter the AC voltage measurement C the tester default Auto range status by click AC auto range d Manual range can be select press th...

Page 92: ...al range c Manual range 0 000mA 6 6mA range 00 00mA 66 00mA range 000 0mA 660 0mA range 00 00A 10 00A range use 10A socket d Select the range to enter current measurement NOTE When only the figure OL...

Page 93: ...600mA range 00 00mA 66 00mA range 000 0mA 660 0mA range 00 00A 10 00A range use 10A socket Note When only the figure OL is displayed it indicates over range situation and the higher range has to be s...

Page 94: ...K 66 00K range 000 0 K 660 0K range 0 000 M 6 600M range 00 00 M 66 00M range F Continuity Testing a Connect the black test lead to the COM jack and the red test lead to the V jack b to select enter t...

Page 95: ...nish the testing quickly without view the screen H Capacitance Measuring a Connect the black test lead to the COM jack and the red test lead to the V jack b Select to enter enter the capacitance measu...

Page 96: ...ately should not test in the installation of circuit b To avoid electric shock be sure the capacitors have been discharged fully before measuring the ca pacitance of a capacitor c While testing the ca...

Page 97: ...d limit time work If input voltage over 600V will damage the meter mA current fuse range 250V 1A if the current over the rated range fuse will melt to protect the meter Pls use the same model when cha...

Page 98: ...ile testing set the wavelength for measurement Click relative difference to test the tester Auto save current fiber power value as the base reference value Input another optical fiber to be measured t...

Page 99: ...can select Steady mode Evasive 1Hz Evasive 2Hz and Time off Click button Steady mode to enter steady status click button Evasive 1Hz and Evasive 2Hz to enter pulse mode click button Time off VFL is t...

Page 100: ...5 Click Steady mode red laser source emits steady click again to quit Click icons Evasive 1Hz or Evasive 2Hz to enter pulse mode the red laser source is emitted by a certain frequency press it again t...

Page 101: ...ard send the code to the tester if it can be read the protocol will shown on the upper right like Pelco D if not like P While the tester receives the code press the key to empty Though the RS485 port...

Page 102: ...video formats of MP4 H 264 MPEG4 and MKV The IP tester recorded files can play directly via the Media player The Media player will automatically display the video files from the SD card Click on the d...

Page 103: ...e to view your camera via the ONVIF or IPC Test apps it is possible your camera will have an RTSP stream and you can view live video From the main menu select the APP Tool folder and then select the R...

Page 104: ...necessary information select Enter at the bottom left to view the RTSP stream Note In the event the ip tester does not auto detect the rtsp stream refer to the specific camera manufacturer for the spe...

Page 105: ...n camera to the tester it will auto identify and display Unactivate at safety mode Select needed activate the camera click bottom right corner button Enable pop up the camera have not been activated a...

Page 106: ...gram default modifies the camera IP Activated multiple cameras in the local area Network and pop up menu to modify IP improve project efficiency Play Display image from the camera Modify network infor...

Page 107: ...nd password Factory Reset Camera factory reset 3 3 35 Dahua test tool Dahua test tool is developed for installation and debugging of the Dahua IP camera it can display image modify IP user name and pa...

Page 108: ...Page 103 Click DH icon to enter Dahua test tool Select the camera of the online detection menu if the camera support non verification login you can click play directly and view the image...

Page 109: ...test If the camera not supports non verification login pls select camera of online detection menu and input correct user name and password then click log in After logging successful you can test it Pl...

Page 110: ...ify user information Modify camera user name and password which is onvif Dahua test tool IPC TESTE user name and password not web user name and password Factory reset setting Camera will be soft reset...

Page 111: ...Update menu Select Local Update to update via the SD card or select Online Update to check for updates on the internet If there are applications that need updating the applications will be displayed...

Page 112: ...ntenance in the evening or in the dark Click icon to enter While in the flashlight app click the red button to turn on the LED lamp Press it again to turn it off If you don t press the red button to s...

Page 113: ...camera and IP tester be on the same network segment for the browser to interface with the camera If they are not in the same segment click the button or press RETRUN to exit Open the Settings app fro...

Page 114: ...ay Click each record bar to show the details Press the record bar for several seconds prompt whether delete it 3 3 41 System Setting Click icon to enter Language Select your desired language English C...

Page 115: ...location to use DHCP To test multiple network segments click Advanced and then click Add to enter another IP address for the IP tester After setting an advanced IP address refer to the photos above th...

Page 116: ...Page 111 Select and press WIFI several seconds to set static IP address Wi Fi hotspot input SSID name and password and then click ok to create Wi Fi hotspot...

Page 117: ...g it FTP server Once the IP tester connects to a network a computer can be used to read the SD card files via FTP Start the FTP server and then input the tester s FTP address in the PC s address bar T...

Page 118: ...assword Lock Screen Set password you can input digitals letters or characters as password input it again to confirm when the meter is in standby mode or turn it on you can input your password to enter...

Page 119: ...4 Browse It includes Music Videos Pictures Documents zip file etc It is convenient to view and manager FTP server You can choose internal or external SD card Other operation details Pls refer to FTP s...

Page 120: ...Lite mode or normal mode Theme Pressing square area s any color icon several seconds the selected color icon will be auto move the rectangle area if you press selected color several seconds and it wi...

Page 121: ...finished color setting click set to set it as desktop or application background Set as desktop background Setting color as desktop background Set as application background Set color as application ba...

Page 122: ...ck more to select pictures from local file and click set to set picture as background Sliding effect Tester s sliding effect includes stereo effect folding effect Left and right folding rotate effect...

Page 123: ...to 1080P resolution 3 6 PoE power output The IP tester supports PoE Power over Ethernet output to an IP camera via the LAN port Data transmission and 48VDC use the network cable s 1 2 3 and 6 pins to...

Page 124: ...2A power output When the IPC tester is turned on the DC 12V power output ON by default The smaller end of the supplied converter cable connects to the tester s DC12V 2A OUTPUT and the other end conne...

Page 125: ...nnect all cables from the tester and reboot it to resume using the tester The IPC tester power output is close to 2A if the IP camera s power is over 2V the tester will auto enter protection mode Disc...

Page 126: ...p 1280 1024p 1280 900p 1440 900p HDMI output 1 channel HDMI output supports up to 3840 2160p IP discovery Auto scan the whole network segment camera IP Rapid ONVIF Search camera quickly auto log in an...

Page 127: ...ayback Capture current images and record live video as JPG file Media player will view photos and playback video 12V 2A power output Output DC12V 2A power to camera USB 5V power output 5V 2A power out...

Page 128: ...AC DC current Resistance Capacitance Data hold Relative measurement Continuity testing Testing speed 3 times seconds Data range 6600 6600 Optical power meter Optional Calibrated Wavelength nm 850 1300...

Page 129: ...e 3times s Current modes for clamp meter with ZERO function Isolation the Multi Meter connector must be isolated with the other connector DC voltage Range Accuracy Resolution 660mV Manual range 0 3 4...

Page 130: ...nt Range Accuracy Resolution 6 600mA 0 5 3 1uA 66 00mA 10uA 660 0mA 100uA 10 00A 1 5 10mA Resistance Range Accuracy Resolution 660 0 0 8 5 0 1 6 600K 0 8 2 1 66 00K 10 660 0K 100 6 600M 1K 66M 1 2 5 1...

Page 131: ...solution 6 600nF 0 5 20 1pF 66 00nF 3 5 8 10pF 660 0nF 100pF 6 600 F 1nF 66 00 F 10nF 660 0 F 5 8 100nF 6 600mF 1 F 66 00mF 10 F 4 3 Optical power meter specifications Measure Range dBm 70 10dBm Wavel...

Page 132: ...power 5mW Optional 10mW 20mW Modulation mode CW 1Hz 2Hz Measurement Range 5KM Optional 10 20KM Connector FC PC exchangeable Working Temperature 10 50 Operating Temperature 20 70 The data above is onl...