background image

7

 ATTO Technology FibreBridge 3300D Installation and Operation Manual

4 Connecting SCSI devices to SCSI ports

ATTO FibreBridge SCSI ports are used to connect SCSI storage devices into the Fibre Channel Storage 
Area Network (SAN). 

Each SCSI port is totally independent from the 
any other SCSI port. This means that each bus is 
capable of supporting 15 devices and each bus is 
capable of 80 or 160 MB/sec. (Ultra, Ultra2 or 
Ultra160). 

However, you may use externally provided 
software striping to create a RAID 0 group that 
includes devices from both SCSI busses to 
increase overall performance. 

Another advantage of independent SCSI ports is 
that each SCSI bus auto-negotiates the 
appropriate sync rates with the connected devices. 
If slower devices are mixed with faster Ultra160 
devices, the bus will communicate at the rate of 
the slowest device, thus wasting the performance 
capabilities of the faster devices. You should 
connect slower devices to one SCSI port and 
connect faster devices on the other port on your 
FibreBridge. 

The FibreBridge supports a wide variety of SCSI 
storage devices including stand-alone drives, 
removable drives, JBODs, RAIDs, tape, CD and 
DVD drives, changers, and libraries, magneto 
optical drives.

To connect SCSI devices to the ATTO 
FibreBridge: 

1

C

onnect a VHDCI connector from the SCSI 

device to a port on the FibreBridge 3300.

2

Check the type of cable, cable length limit 
and number of devices recommended for 
each port. It is important to keep cable 
lengths as short as possible to ensure the 
highest signal quality and 
performance.These cable lengths include 
the wiring inside the devices. 

3

Set the IDs of the SCSI devices connected to 
the bridge to a value other than 7. It is 
recommended to use a sequential ID 
starting at 0 for each device. Each SCSI port 
in the ATTO FibreBridge has an internal 
factory setting ID of 7, typical for a SCSI 
initiator device. 

NOTE The entire SCSI bus will operate at the speed of the 
slowest device. If you wish to mix devices of different SCSI 
speeds on the bridge, it is best to place them on separate 
busses. That is, put the slower devices on bridge SCSI bus 0, 
and the faster devices on bridge SCSI bus 1. Each bus is 
independent so each can operate at different speeds.

4

Terminate each SCSI bus after the last 
device. The bridge is terminated internally. 

Device type

Cable limit

Ultra SCSI Single Ended (SE)

1.5 meters

Ultra SCSI High Voltage Differential (HVD)

25 meters

Ultra2 SCSI Low Voltage Differential (LVD)

12 meters

Summary of Contents for FibreBridge 3300R

Page 1: ...TTO Technology Inc All rights reserved All brand or product names are trademarks of their respective holders No part of this manual may be reproduced in any form or by any means without the express wr...

Page 2: ......

Page 3: ...Access the ATTO FibreBridge over the RS 232 port Configure the ATTO FibreBridge for a network over the Ethernet port Access the ATTO FibreBridge using Telnet or FTP over Ethernet 7 Using ATTO FibreBr...

Page 4: ...tus FcTargets FcWWName FibreBridgeTargetLUN Performance ServicesLUN 7 1 5 SCSI configuration commands 23 ScsiInitID ScsiPortBusSpeed ScsiPortList ScsiPortResetOnStartup ScsiPortSelTimeout ScsiPortSync...

Page 5: ...port 31 7 3 ATTO BridgeTools provides graphical interface 33 7 4 FibreBridge menu provides CLI interface 34 8 ATTO FibreBridge addressing 35 9 Handling multiple initiators 37 10 Serverless backup sup...

Page 6: ...brary CD ROM library or JBOD SANs maintain greater fault tolerance and load balancing by supporting server clustering and failover the ability for one server to take over for another in the event of a...

Page 7: ...of a device NL port a port attached to a node in Fibre Channel arbitrated loop or fabric loop configurations N_port a port attached to a node used with point to point or fabric configurations RAID Ori...

Page 8: ...ch enclosure see Chapter 3 ATTO Technology FibreBridge software executes from the Intel 80303 an integrated I960JT processor and PCI PCI bridge 128 MB SDRAM capable of 800 MB sec Qlogic ISP3300 Fibre...

Page 9: ...igabit 1 Gigabit 2 Gigabit 1 Gigabit 2 Gigabit 1 Gigabit SCSI ports 1 2 2 2 2 2 4 SCSI bus number sb 0 0 1 0 1 0 1 0 1 0 1 0 1 2 3 Configuration Board Desktop Board Desktop Rackmount Board Desktop Rac...

Page 10: ...connect the FibreBridge to either a Fabric or Arbitrated Loop 2 125 Gigabit sec Class 2 Class 3 and ANSI Fibre Channel specifications support PLDA Public Loop Login NL_port and Fabric Direct Connect N...

Page 11: ...R plus the cumulative power draw of the other equipment in the rack do not overload the supply circuit and or wiring of the rack Properly ground the FibreBridge 3300R to the rack equipment The earth g...

Page 12: ...s RAIDs tape CD and DVD drives changers and libraries magneto optical drives To connect SCSI devices to the ATTO FibreBridge 1 Connect a VHDCI connector from the SCSI device to a port on the FibreBrid...

Page 13: ...are anchored securely at both ends with the proper connectors Initial configuration The FibreBridge can be configured to support connectivity to arbitrated loop or fabric topologies See Chapter 8 of t...

Page 14: ...s The ATTO BridgeTools program currently supports Sun Solaris 8 MAC OS 10 1 Linux and Windows 95 98 ME NT and 2000 Refer to the ATTO BridgeTools manual for complete instructions to how to install and...

Page 15: ...ibreBridge Configuration Menu select FibreBridge Name 3 Enter the desired FibreBridge Name The name can be no more than eight characters Choose a meaningful name to make identification of the unit eas...

Page 16: ...ices to communicate with the FibreBridge You can choose between an in band connection direct over the Fibre Channel link an RS 232 port or an Ethernet port A tabbed panel interface presents configurat...

Page 17: ...lease date Jan 16 2002 16 22 00 Build A07B Power On Self Test Completion Status GOOD 128 Megabytes of RAM Installed 1 2 1248 Gb s Fibre Channel Arbitrated Loop Interfaces 2 LVD SCSI Interface Ports In...

Page 18: ...estart of the system before it is implemented The restart can be accomplished as part of the SaveConfiguration command or by using a separate FirmwareRestart command A number of set commands may be is...

Page 19: ...tition of preceding item n end of line a range 6 9 6 7 8 9 Boldface words must be typed as they appear Italicized words Arguments which must be replaced by whatever they represent fl Fibre Channel lun...

Page 20: ...command name is specified displays detailed command specific information Action none Information Help command name Info Displays version numbers and other production information for key components wit...

Page 21: ...e configuration If a firmware restart is required to make the requested change permanent you will see a prompt asking you to confirm the restart You can override this request by indicating the overrid...

Page 22: ...w the mini mum MinEnclTempAlrm thermal control event handling occurs Limits valid entries are between 0and 70 degrees and below the current maximum enclosure temperature alarm Default 0o C Actions set...

Page 23: ...he ZMODEM file transfer protocol Limits available only through the RS232 interface WARNING After a firmware image is downloaded to the FibreBridge the image is placed into flash memory During this tim...

Page 24: ...rning unexpected situation condition 0x04 Critical operation limited curtailed 0x08 Failure hard failure 0x10 Other 0x20 Debug ATTO tracking events Actions set DispEvent subsystem event_level status S...

Page 25: ...on limited curtailed 0x08 Failure hard failure 0x10 Other 0x20 Debug track events Actions set LogEvent enabled disabled subsystem event_level status Information getLogEvent SaveConfiguration ParityLog...

Page 26: ...l Fibre Channel ports Default loop Actions set FcConnMode loop ptp Information get FcConnMode SaveConfiguration FcFairArb Turns the Fibre Channel Arbitrated Loop FC AL arbitration fairness on or off W...

Page 27: ...ports the Word Wide Name WWN of the Fibre Channel interface Each FC port has an individual and unique WWN The least significant 6 bits of the WWN are used as the Ethernet MAC address Limits Fabric and...

Page 28: ...PortBusSpeed Port Number fast ultra ultra2 Information get ScsiPortBusSpeed SaveConfiguration ScsiPortList Returns a list of available SCSI ports and their current status Limits valid status values ar...

Page 29: ...ScsiTermination Configures reports the SCSI internal termination of the SCSI port identified Default enabled Action set ScsiTermination sb enabled disabled Information get ScsiTermination sb SaveConf...

Page 30: ...yboard input When enabled all non control character keyboard input is output to the display Limits Local ASCII terminal or terminal emulator echo settings should be set to disabled while using SerialP...

Page 31: ...s the current FibreBridge IP address Limits If IPDHCP is enabled see below get command reports current IP address assigned by DHCP server Default IP Address 010 000 000 001 Actions set IPAddress xxx x...

Page 32: ...reBridge will complete any current SCSI commands for the mapped device and will reject any subsequent SCSI commands for that device 2 When all current SCSI commands for the device are complete the dev...

Page 33: ...get form reports all FibreBridgeTargetLUNs currently NOT disabled Specifying a port returns the status of that port Action set FibreBridgeTargetLUN fp fl disabled Information get FibreBRidgeTargetLUN...

Page 34: ...gets Returns a list of SCSI devices operational on the referenced SCSI port Also updates the status of any online maps routes to unavailable if a device is not found or online if a device is found Act...

Page 35: ...et XCDevices CmdNumber Return lineCount DeviceType VendorID ProductID SerialNumber DataDirection SCSI type VendID ProdId xxxxxxxxxxxxxxxx DataDir XCError Retrieves any SCSI sense data returned by an E...

Page 36: ...n will not be allowed to modify the FibreBridge configuration If you try the results buffer of the ServicesLUN will return Process X has the configuration reserved ID of this session Y Ready 2 The ini...

Page 37: ...et is always 0 Exhibit 7 2 1 The SCSI command process reserve the FibreBridge send the command release the FibreBridge Initiator Host FibreBridge Goal reserve the FibreBridge for an in band CLI comman...

Page 38: ...dge model is available and presents you with the applicable configuration options The ATTO BridgeTools program currently supports Sun Solaris 8 MAC OS 10 1 Linux and Windows 95 98 ME NT and 2000 Commu...

Page 39: ...follow this is the last choice If you wish to change the you type in your response to Enter FibreBridge Name Max of 8 characters In the FibreChannel Configuration Menu choosing Port Connection Mode lo...

Page 40: ...assignment commonly referred to as hard and soft addressing Soft addressing allows the loop initialization master to assign the FibreBridge a unique AL_PA during the loop initialization process The A...

Page 41: ...these devices on the Fibre Channel ports In the chart at right the SCSI device on SCSI bus 0 at SCSI address of ID 0 LUN 0 is being mapped to Fibre Port 0 on the FibreBridge at Fibre Channel LUN 4 No...

Page 42: ...a check condition with Reservation Conflict to the Initiator If there is no conflict the FibreBridge marks the SCSI device as Reserved in its internal database Tier 2 4 The FibreBridge relays the Res...

Page 43: ...Fibre Channel Initiator 1 sends the command Reserve through the FC AL to FibreBridge 1 2 FibreBridge 1 determines the command is valid 3 FibreBridge 1 sends the command Reserve to the SCSI target 4 Th...

Page 44: ...w the host to describe the devices involved in the Extended Copy To be compatible with all copy agent application packages the FibreBridge implementation supports World Wide Name N_Port ID and WWN plu...

Page 45: ...e identifier for a particular Extended Copy command 3 Type get XCDevices CmdNumber to find out which devices are used in a particular Extended Copy command as specified by the CmdNumber 4 Type get XCE...

Page 46: ...mprove the performance of FCP WRITE commands to SCSI devices attached to the FibreBridge Using the CLI command SpeedWrite you can specify the SCSI bus target and LUN of a mapped device or specify all...

Page 47: ...e download is complete cycle power on the FibreBridge to implement the new firmware To use the ZModem command over the serial link to load new firmware 1 Uncompress the JAR file obtained from the ATTO...

Page 48: ...t to point get fcconnmode 21 FcFairArb Enabled get fcfairarb 21 FcFullDuplex Enabled set fcfullduplex disabled 21 FcHard Disabled get fchard 21 28 FcHardAddress FC Port 0 0x03 get fchardaddress 0 21 2...

Page 49: ...PortSelTimeout 64ms set scsiportseltimeout 2 128 23 ScsiPortSyncTransfer enabled set scsiportsynctransfer 0 disabled 23 ScsiPortTaggedQueuing disabled set scsiporttaggedqueuing 2 enabled 24 ScsiPortWi...

Page 50: ...et RouteOnline 0 3 fp fl sb st sl On Offline 0 3 3 0 0 Online Ready RouteDisplay 0 3 6 fp fl sb st sl On Offline 0 3 3 0 0 Online xx xx 0 7 0 Reserved xx xx 1 7 0 Reserved xx xx 2 7 0 Reserved xx xx 3...

Page 51: ...x Offline 2 0 0 2 0 Online 2 1 1 2 0 Online 2 2 2 2 0 Online 2 3 3 2 0 Online 2 4 xx xx xx Offline 2 5 xx xx xx Offline 2 30 xx xx xx Offline 2 31 xx xx xx Offline xx xx 0 7 0 Reserved xx xx 1 7 0 Res...

Page 52: ...evice offline FC 0 Lun 1 Setting device offline FC 0 Lun 2 Setting device offline FC 0 Lun 7 Setting device offline FC 1 Lun 0 Setting device offline FC 1 Lun 1 Setting device offline FC 1 Lun 2 Setti...

Page 53: ...g device offline FC 0 Lun 7 Setting device offline FC 1 Lun 0 Setting device offline FC 1 Lun 1 Setting device offline FC 1 Lun 2 Setting device offline FC 2 Lun 0 Setting device offline FC 2 Lun 1 Se...

Page 54: ...nce to radio and television reception which can be determined by turning the equipment off and on try to correct the interference by one or more of the following measures Move the receiving antenna Re...

Page 55: ...on and found to be compliant with the following European Union standards Application of Council Directive 89 336 EEC Standard s to which conformity is declared EN55022 EN50082 1 This Declaration will...

Page 56: ...a SCSI Bridge CPCI Board FCBR 4500 CL0 Fibre Channel to LVD Ultra2 SCSI Bridge CPCI Board Desktop Rackmount FibreBridge 1180 FCBR 1180 DLC Fibre Channel to LVD Ultra2 SCSI Bridge with Copper DB9 Fibre...

Page 57: ...annel Cable Unequalized 10m CBL HSHS 003 HSSDC to HSSDC Copper Fibre Channel Cable Unequalized 3m CBL HSHS 010 HSSDC to HSSDC Copper Fibre Channel Cable Unequalized 10m Cables Optical CBL FCFI 005 5 M...

Page 58: ...ble by phone Monday through Friday Eastern Standard Time 8 00 a m to 8 00 p m or by fax and web site 24 hours a day ATTO Technology Inc 155 CrossPoint Parkway Amherst New York 14068 716 691 1999 voice...

Reviews: