Placement of Q-Tee II
Installation distance from a combustible wall
The stove is placed on a non-combustible floor.
Using non insulated 150mm I.D. flue pipe, the minimum distance to combustible wall
must be 450 mm from the flue.
Normal set-up - corner
setting
Uninsulated flue
Insulated flue
Uninsulated flue
with Reflector
A. Distance to furniture (min.)
1200 mm
1200 mm
1200 mm
Distance to flammable materials (min.)
B. in front (floor)
575 mm
575 mm
575 mm
C. to the side (floor)
if distances are not shown,
national/local regulations are followed
D. to the rear (wall)
400 mm
350 mm
200mm
E. to the side of the wall
400 mm
400 mm
400mm
Q-TEE II on a 250 mm high log store
If the stove is to be installed on a wooden floor, it must be covered
with a non-combustible material at least 12 mm thick, in accordance
with UK Building Regulations
Approved Document J. The stove is to be elevated min. 250 mm, for
example placed on a non-combustable base.
Distance to flammable materials (min.)
B. in front (floor)
300 mm
300 mm
300mm
D
E
B
A
Without Reflector
With Reflector