Appendix Nr.1
PELLET BURNER
PELH30A
MANUAL FOR ATTENDANCE
Manual for installation and start-up
EN - 01.07.2010
Page 1: ...Appendix Nr 1 PELLET BURNER PELH30A MANUAL FOR ATTENDANCE Manual for installation and start up EN 01 07 2010...
Page 2: ...How to install pellet burner 14 Burner start 14 Burner stop 14 Emergency stop 15 Cleaning and maintenance 16 Troubleshooting 17 Possible causes of faults 18 Decomposed view 19 Spare parts and codes 2...
Page 3: ...ions between boiler and chimney have to be airtight Overpressure in combustion chamber has to be min 5 Pascal 0 5mm of water column resp 0 05hPa The PELH30A appliance is intended for combustion of woo...
Page 4: ...t via menu buttons of burner and information on dipslay It possible to change range of output in two levels from 8 to 12kW and from 14 to 30kW and according to this there are three degrees of output f...
Page 5: ...lity If the box is damaged check burner for possible damage by transport Reclamation of damage by transport has to be recorded by spediteur Paper box shoul content these parts 1 pc Burner PELH30A 1 pc...
Page 6: ...WARNING Electrical installation has to be done by certified electrotechnician Main cables can be replaced only by eletrotechnician approved by us Voltage and energy consumption Component Mains Volt M...
Page 7: ...leaned grate moves out towards scraper and ash with unburned elements falls through fron wall of the burner s bottom into the ashpan After the grate shifted the burner waits for new signal from thermo...
Page 8: ...us operation demand for pellet feeding Pellets have to be stored in well ventilated room without moisture or in specially adjusted container NOTE PELH30A consists from components of high quality that...
Page 9: ...ing schedule MENU Explanation EFFECT ADJ Required output degree 1 2 or 3 PELLET TRIM Setting of feeded pellet ration LOG Record of faults for control purposes FINAL COMBUST Instruction to burner for b...
Page 10: ...reasing amounts of pellets are feeded into burner until required pellet ration is achieved Step 4 Combustion Combustion phase runs until it is interrupted by thermostat Step 5 Burn out Thermostat inte...
Page 11: ...terrupt operation from other reasons press the M button and the burn out regime begins For burner restart after ash removing press M Press the button This internal setting can be helpful by trobleshot...
Page 12: ...1 2 3 8 10 12 14 22 30 8 12 14 30 kilowatt kilowatt Ignition setting 90 50 300 Test blow time 15 0 60 sec Transition phase 240 480 60 600 sec Transition pellet trim 15 10 50 Clean blow time 45 10 600...
Page 13: ...12 Menu Settting See Extended Menu Log Saves error codes See Extended Languages Slovak English German Italian French Polish...
Page 14: ...ing way by pressing of button go to Save settings and save your settings by M button Exit menu by E button Regulation of pellet dosing Before starting up of burner it is necessary to set pellet feedin...
Page 15: ...een feeder s opening and inlet pipe of min 400mm In horizontal position there should be gap between inlet pipe and feeder s opening of min 1500mm i e not vertically aligned Fill container with pellets...
Page 16: ...hermostat gives instruction to stop Burner is alternatively controled by thermal boiler sensor connected to TS1 inlet on the right upper side of the circuit board Make sure that connection is fixed in...
Page 17: ...l the fuel in burner burns out Turn the burner off by burner switch and by the main switch plug out mains cord of the boiler from mains socket Open door with burner to cca 90 1 Put down burner cover a...
Page 18: ...cell abnormal light 12 ERROR CIRCUIT BOARD OVERHEATED Temperature under cover is too high 13 ERROR TEMPERATURE SENSOR TOO LOW Faulty thermal sensor of built in operation thermostat 14 ERROR TEMPERATUR...
Page 19: ...high temperature in boiler room Prevent from heat leakage 14 Faulty sensor of thermostat Replace sensor 15 Faulty sensor of thermostat Replace sensor 16 Faulty circuit board Replace circuit board 18 V...
Page 20: ...19 Decomposed view...
Page 21: ...Shield with covering bracket 14 Hearth covering 15 Sealing flange 16 End switch bracket 17 Pellet brake 18 Pin of end switch 19 Blind of suction 20 Tension spring 21 Platform of display 22 Burner cove...
Page 22: ...21 El scheme of connection burner PELH30A...
Page 23: ...removing 1 230 VAC Phase 2 230 VAC Directly earthed conductor 3 230 VAC Phase of thermostat 4 Ventilator Directly earthed conductor 5 Ventilator Phase 6 Feeder Directly earthed conductor 7 Feeder Phas...
Page 24: ...23 Accessories Name Number Ashpan Pellet container 300l PEL9600 Pellet feeder 1 5 m long Pellet feeder 2 5 m long Pellet feeder 5 m long...
Page 25: ...act person and electrotechnician Date of installation Installed by Address street ZIP Code City Telephone Cell phone Service record Date Servised Checked CO2 Flue gas temperature CO ppm Service perfor...
Page 26: ...tom corner will be O 14 i e actual value of actuator output in kW To change actuator output press button until required value is displayed in the right bottom corner i g N 18 If you press M now this n...
Page 27: ...mount feeded into burner after fire recognition Feeded amount will be gradually increased with every ration during set period Pre set from production is 15 from full ration for14kW Time setting of cle...
Page 28: ...re is possibility to select these languages Slovak English German Italian French Polish Setting of output range Burner can operate in the output range of 8 12 kW or 14 30 kW acoording to the range sel...
Page 29: ...t is possible to reload production or installation settings Accessible are three main options Loading of settings Saving of settings and Production settings Loading of settings means that you can rese...
Page 30: ...ber Pellet feeder Trademark Length Serial number Settings of pellet burner Menu Production settings Options of settings Set to Output level 1 14kW 1 2 3 ON OFF temperature ON 72 C OFF 82 C Difference...
Page 31: ...Settings of pellet burner Menu Production settings Options of settings Set to Output level 1 14kW 1 2 3 ON OFF temperature ON 72 C OFF 82 C Difference min 5 Pellet ration 95 50 200 Advanced menu Rando...
Page 32: ...upozornenia ATTACK s r o producer reserves theright tochangetechnical parametersand dimensions of boilerswithout previous warning Der Hersteller ATTACK s r o beh lt sich das Recht der technischenVer d...