31
Maintenance and Service
Turbine Module Box
Ensure completion of the service check of the turbine module box after maximum 100 hours or once a
year. ATT has the only authorised workshop for repair and service checks.
Air filter
Inspect the air filters daily. Replace the air filter(s) if they are soiled or blocked or in any way unserviceable.
Filter cap
Inspect the filter cap daily. Clean and check for any damage or other elements, which can prevent full
functionality
Turbine Module Box Replacement
1)
Remove the filter cap.
2)
Loosen the quick releases on both sides of the
Turbine Cover.
3)
Lift and remove the Turbine Cover.
4)
Release the electric plug.
5)
Release the fuel hose quick release.
6)
Remove the 4 screws on the Nozzle Cover Plate.
7)
Pull out the turbine module box.
Once the new turbine module box is installed, ship the replaced turbine module box to Applied Turbine
Technologies for service etc.
Pack the replaced turbine module box into the dedicated transport box, state your contact details on the
supplied shipment label, place the label on the transport box and return the parcel.