 For Safety Installation

1. Read the following carefully prior to installation.

CAUTION!

Do not install outdoors.

Avoid intense shock or vibration.

Avoid intense electrical or electromagnetic noise.

Avoid magnetic material.

Avoid corrosive gas and dust.

Avoid direct exposure to sunlight and intense light.

Do not install in the areas where sudden temperature fluctuation is expected.

Avoid vapor or high humidity that can cause condensation.

Install within 2.5 - 6.0m (8 - 20ft.) height from floor.

Install and set up the unit so that intruders will cross field of view.

Avoid partitions, furniture and glass within coverage.

Catch performance is based on the temperature difference between a moving object and a stable background.
The greater the difference, the longer the actual range.

2. Read the following prior to installation and regular maintenance.

WARNING!

Do not wire the unit when it thunders.

Do not disassemble or modify the unit.

Power must be cut off during wiring.

Keep power between 9 - 28 VDC at all times.

ATTENTION!

Avoid intense shock and vibration.

After installation and setup, perform walk test in the protection area to check if alarm is activated.  Mirrors, partitions
and walls with high reflectance may detect temperature difference beyond the specified range.

Make sure no objects will block the detector's field of view.

Use curtains and blind in case the detector is exposed to sunlight and intense light.

Do not install near fax machine, heater and air conditioner as they may cause heat fluctuation.

3. Remarks

Moving objects in the gap of detection zones cannot be detected.

Static objects including human body cannot be detected.

This unit is designed to detect infrared energy variations caused by the movement of human body.
Similar variations in the specified range may cause the detector to activate an alarm. In case the temperature
difference between the moving human body and the stable background is very small, the detector may not detect
the movement.

2

 Components

Make sure the following items are included in the package prior to installation.

Quantity

1

2

Description

Installation Manual

Quantity

1

IR36EXA

Installation Manual

We thank you for purchasing ATSUMI passive infrared detector. Please read this installation manual
carefully for appropriate use of the product.

Description

Detector (Base & Body Units)

Mounting Screws (ø4 x 32)

PASSIVE INFRARED DETECTOR

Summary of Contents for IR36EXA

Page 1: ...alk test in the protection area to check if alarm is activated Mirrors partitions and walls with high reflectance may detect temperature difference beyond the specified range Make sure no objects will...

Page 2: ...0 80 AWG20 If more than one detector is added to the loop the maximum length per gauge decreases and is determined by dividing the length found in the chart by the number of detectors on the loop Use...

Page 3: ...2 Firmly mount the base unit on ceiling with the mounting screws provided and route wiring as necessary to the rear of the base and through the wiring hole 3 Determine initial setup Please refer to 6...

Page 4: ...detects malfunction of the unit Selection This function is active at all times regardless of switch settings Functions If the Alarm LED continues to blink after the one 1 minute warm up period a malfu...

Page 5: ...eter height and 8 meter coverage 1 SIMULTANEOUS SETUP Rotate the adjusting plate to align V shaped protrusion with the desired mounting height In this case coverage of 20 meters in diameter is achieve...

Page 6: ...wire Alarm output is connected in parallel with other outputs of the unit Self diagnosis is active due to the malfunction of the unit Remedy Remove the blocking objects Readjust coverage Turn the swi...

Page 7: ...30VDC 0 1A resistor load 5 0 or less Form 1b NC contacts open when either body unit is detached from the base unit or base unit is removed from ceiling 30VDC 0 1A resistor load 1 0 or less 0 3 2 0m s...

Page 8: ...ion on 9 Walk Test If furniture and or partition are moved in the coverage area Walk Test should be conducted At least once a year the whole system should be checked The user also needs to check the f...

Reviews: