System Specifications
SuperTrak™ GEN3 System Operation and Maintenance Manual
275
Rev. 9 (12-2021)
Electrical Services
Electromagnetic Compatibility (EMC) Requirements for
High-Frequency Emissions
The following table provides the high-frequency emissions in accordance with
EN 61000-6-4:
Service
Specification
Value
Control panel
Line voltage
208PE
Or
400PE
Frequency
50/60 Hz
Phases
3 ph, 5-wire
Short circuit current rating
5kA
Largest load
20A
Control voltage
24VDC (digital power supplied
from the control panel)
28VDC (motor power supplied
from the power supplies)
Full load amps
36A
UPS (located
inside the control
panel)
Line voltage
24VDC
Frequency
50/60 Hz
Current rating
15A
Emission
Test Accordance
Class
Emission
Conducted emissions
IEC 55011
Class A Group 2
150 kHz - 30 MHz
Radiated emissions
IEC 55011
Class A Group 2
150 kHz - 1000 MHz