270
SuperTrak™ GEN3 System Operation and Maintenance Manual
Rev. 9 (12-2021)
Troubleshooting
Coil Driver Board (ACB3000) Indicator Lights
The coil drive board has two (2) indicator lights: one green, and one red.
G
10 (TEMP)
d
Yellow
ON
The gateway board is the last in the
network.
OFF
The gateway board is not the last in
the network.
a. STAT stands for status.
b. COMM stands for communication.
c. CURLIM stands for current limit. Note that the text does not correlate to the LED function.
d. TEMP stands for temperature. Note that the text may not correlate to the LED function. Gateway
boards that were manufactured before mid-2016 and have not received a CPLD firmware update
use the yellow LEDs as follows: ON=defective thermistor detected, blinking fast=the operating tem-
perature limit is exceeded, OFF=the motor temperature is within operating range.
Indicator
Light
Light State Normal
A Problem May Exist
Green
ON
(power is ON)
OFF
The power is OFF.
Red
ON
The A/D CPLD is not programmed. Contact your
vendor for assistance.
OFF
ID
LED #
Color
Light State
Normal
A Problem May Exist
Summary of Contents for SuperTrak GEN3
Page 1: ...Rev 9 December 2021...
Page 2: ......
Page 3: ...SuperTrak GEN3 Conveyance Platform Modular Conveyor Operation and Maintenance Manual...
Page 6: ......
Page 12: ...This page is intentionally blank...
Page 30: ...This page is intentionally blank...
Page 58: ...This page is intentionally blank...
Page 296: ...This page is intentionally blank...
Page 300: ...This page is intentionally blank...
Page 364: ...This page is intentionally blank...
Page 366: ...This page is intentionally blank...