266
SuperTrak™ GEN3 System Operation and Maintenance Manual
Rev. 9 (12-2021)
Troubleshooting
Test the Rail System
1. Inspect both the flat and upper v-rail for any damage or debris build-up.
2. Inspect the flat rail, to verify that the wear strip is correctly seated in the
groove of the track structure.
3. Slowly, manually move a pallet fully across a straight or curved section. As you
move the pallet, feel for any resistance in pallet motion.
4. Verify that the alignment of the upper v-rail is correct between every straight
section and between the straight sections and curved sections.
5. Verify that the alignment of the flat rail is correct between every straight
section and between the straight sections and curved sections.
Test a Magnetic Shunt
1. Manually move a pallet over straight section and curved section joints. Feel for
an excessive amount of resistance (magnetic bump).
2. If necessary repeat this in several locations to obtain a baseline of what the
magnetic bump should feel like.