Technician Procedures
SuperTrak™ GEN3 System Operation and Maintenance Manual
219
Rev. 9 (12-2021)
Center a Pallet Setup Stationary Mount with an Encoder
1. If required, install a stationary mount.
Install a Pallet Setup Stationary Mount
2. Install the chip finder on the left side of the stationary mount:
a. Align the chip finder with the left
side of the stationary mount.
b. Loosely secure the chip finder in
position using the thumb screw.
c. Firmly hold the chip finder back
and to the left (corner crowd), and
then tighten the thumb screw.
3. In the TrakMaster software, expand
Diagnostics
, and then click
Encoders
.
4. Click the
Fixture Setup
tab.
5. Click the encoder that the stationary mount is aligned with.
For example; if the stationary mount was installed at encoder 3,
“3” would be selected.
6. For step 2 on the TrakMaster screen, click
Accept
.