174
SuperTrak™ GEN3 System Operation and Maintenance Manual
Rev. 9 (12-2021)
Technician Procedures
Replace a Coil Fuse
Each coil driver board has ten (10) 15A fuses; there is a dedicated fuse for each
coil. If a SuperTrak conveyance platform fault indicates that fuse replacement is
required, remove the fuse and test it. If the fuse is blown, replace it. If the fuse is
not blown, verify that the fuse is seated correctly.
The images below indicate correct and incorrect fuse installation.
Replace a Coil Fuse - Straight Section, 90 Deg. Section, or 180 Deg.
Section (800 mm)
1. Turn the
SuperTrak conveyance platform power disconnect switch
to
the OFF position.
2. Lock out and tag hazardous energy.
3. Open the electrical door at the base of the straight section.
4. If access to the fuse is blocked, disconnect the applicable coil connection.
It is possible for the SuperTrak conveyance platform to operate when a
coil fuse is blown; however, the pallet stop control is affected.
Summary of Contents for SuperTrak GEN3