166
SuperTrak™ GEN3 System Operation and Maintenance Manual
Rev. 9 (12-2021)
Technician Procedures
Remove an Encoder Assembly - Curved Sections
1. Turn the
SuperTrak conveyance platform power disconnect switch
to
the OFF position.
2. Lock out and tag hazardous energy.
3. Remove the five (5) encoder assembly screw caps.
Note: The images in these instructions show the 180 deg. (500 mm) section,
but the process is the same for other curved sections.
4. Remove the five (5) encoder assembly screws.
5. Lift the encoder assembly straight up, off the two locating dowels.
6. Disconnect the RJ11 plug
from the encoder assembly
connection.