118
SuperTrak™ GEN3 System Operation and Maintenance Manual
Rev. 9 (12-2021)
Controls and Connections
Main Power Connection
The main power cable (incoming) is wired through the back of the panel and into
the main AC power disconnect connection, as illustrated:
For the power drop connection, phase orientation does not matter.
ID
Connection
Number
Connection
Type
Description
A
N/A
N/A
Main power connection location.
B
N/A
Main power
cable
Main power supply (incoming) port at the back of the
control panel.
C
N/A
Main power
connection
Main power supply (incoming) connections:
• Green - PE (ground)
• Black, Red, Orange - Phase 1, 2, or 3 (in any order)
• White - Neutral
D
12Q0:8
UPS
UPS power goes through the auxiliary contact on the
main disconnect.
Before
After